Telio cs desensitizer, Application – Ivoclar Vivadent Telio CS User Manual
Page 11

11
Te
li
o
C
S
D
e
se
n
si
ti
z
e
r
Telio CS Desensitizer
Application
Telio CS Desensitizer makes the temporary restoration phase more
comfortable for patients, since it reduces the sensitivity of prepared,
and in some cases exposed, dentin surfaces.
– Prepare cavity / abutment
– You may take the impression at this stage or wait until you have
applied the desensitizer (see notes).
– The dentin surfaces should be dry and clean. Keep working field
dry (e.g. cotton rolls).
– Apply Telio CS Desensitizer:
Brush it into the dentin for 10 seconds using a suitable instrument
(brush, applicator brush).
– Carefully disperse excess to a thin layer / dry with an air syringe.
Do not overdry the dentin.
– Fabricate the temporary restoration / provisionally cement restora-
tion (see notes).
Notes
– The application of Telio CS Desensitizer somewhat increases the
adhesion of the light-curing temporary inlay and onlay materials
from Ivoclar Vivadent to the cavity walls. Nevertheless, they can
be removed at the second appointment without difficulty.
– If light-curing temporary C&B materials are used, Telio CS
Desensitizer should be applied after the fabrication of the
temporary. If you apply Telio CS Desensitizer prior to fabricating
the temporary, the material may stick to the tooth structure when
the impression is repositioned into the oral cavity during the
setting/light-curing procedure and may be difficult to remove.
– The application of Telio CS Desensitizer during temporary fabrica-
tion does not affect or limit the choice of the cementation system
or the success of the cementation procedure in the second
appointment. Both conventional and adhesive cementation
systems can be used for cementation purposes.
– The application of Telio CS Desensitizer to enamel does not create
any problems and does not affect the subsequent steps of the
treatment or the materials being used (thoroughly remove excess
desensitizer / dry).
– Telio CS Desensitizer can be applied before or after impression-
taking. The layer thickness is very thin, so that the accuracy of fit
is maintained even if the desensitizer is applied after the
impression-taking. Interaction of the desensitizer with impression
materials are not known (if applied before impression-taking).