Ivoclar Vivadent IPS e.max ZirPress User Manual
Page 41
![background image](https://www.manualsdir.com/files/791241/content/doc041.png)
41
Observe the following notes for the Stain and Glaze firing:
– Conduct the Stain and Glaze firing on a honey-combed firing tray using the stipulated firing parameters.
– Remove restoration from the furnace after completion of the firing cycle (wait for the acoustic signal of the furnace).
– Allow the objects to cool to room temperature in a place protected from draft.
– Do not touch the hot objects with metal tongs.
– If adjustments are required after Glaze firing (e.g. contact points), they may be applied using IPS e.max Ceram Add-On
(see page 46).
Firing parameters for the Stain and Glaze firing
IPS e.max Ceram on IPS e.max ZirPress
B
S
t
➚
T
H
V
1
V
2
L
Cut-Back and Layering Technique
°C/°F
min.
°C/°F/min
°C/°F
min.
°C/°F
°C/°F
°C/°F
Stain firing
403/757
6:00
60/108
725/1337
1:00
450/842
724/1335
450/842
Glaze firing
403/757
6:00
60/108
725/1337
1:00
450/842
724/1335
450/842
Completed IPS e.max ZirPress restoration pressed partially reduced and veneered with IPS e.max Ceram