Provide a

cold

IPS Alox Plunger and

cold

IPS e.max

ZirPress ingots in the desired shade.

Place the

cold

IPS e.max ZirPress ingot into the

hot

investment ring, with shade imprint facing upward.

Then, place the powder-coated side of the IPS Alox Plunger
into the

hot

investment ring.

Place the

hot

and completed investment ring in the center

of the

hot

press furnace using the IPS Investment Ring

Tongs

Press START to start the selected program.

Once the press program is completed, place the hot invest-
ment ring on the cooling grid using the investment ring
tongs and allow it to cool to room temperature.

Provide a

cold

IPS Alox-Plunger and

cold

IPS e.max

ZirPress ingots in the desired shade.

Place the

cold

IPS e.max ZirPress ingot into the

hot

investment ring, with shade imprint facing upward.

Place the

cold

IPS One-Way Plunger 300 g ing the

hot

investment ring.

Place the

hot

and completed investment ring in the center

of the

hot

press furnace using the IPS Investment Ring

Tongs

Press START to start the selected program.

Once the press program is completed, place the hot invest-
ment ring on the cooling grid using the investment ring
tongs and allow it to cool to room temperature.

Procedure for pressing when using the…

IPS Alox Plunger for the IPS Investment Ring System 100, 200 g

IPS One-Way Plunger 300 g for the IPS Investment Ring System 300 g