Ivoclar Vivadent IPS e.max CAD Labside User Manual
Page 63
![background image](https://www.manualsdir.com/files/791239/content/doc063.png)
63
– Crystallization/Glaze HT/LT can only be used for IPS e.max CAD HT and LT.
– IPS e.max CAD MO cannot be crystallized with this program, since it does not crystallize
completely.
– If only max. two restorations are crystallized at the same time, the closing time S can be
reduced to 1:30 min. This reduced time is only for Glaze Spray. Glaze Paste may not be
used.
Furnace
P100
P200
P300
P500
P700
PX1
EP 600
EP 3000
EP 5000
Closing time
S
min.
6:00
6:00
6:00
6:00
6:00
Stand-by
temperature
B
°C/°F
403/757
403/757
403/757
403/757
403/757
Heating rate
t
1
°C/°F/min
90/162
90/162
90/162
90/162
90/162
Firing
temperature
T
1
°C/°F
820/1508
820/1508
820/1508
820/1508
820/1508
Holding time
H
1
min.
0:10
0:10
0:10
0:10
0:10
Heating rate
t
2
°C/°F/min
30/54
30/54
30/54
30/54
30/54
Firing
temperature
T
2
°C/°F
840/1544
840/1544
840/1544
840/1544
840/1544
Holding time
H
2
min.
7:00
7:00
7:00
7:00
7:00
Long-term
cooling
L
°C/°F
700/1292
700/1292
775/1427
1:30 min
700/1292
0:20 min
700/1292
700/1292
Cooling rate
t
l
°C/°F/min
–
0
–
–
0
Vacuum 1
1
1
1
2
°C/°F
550/1022
820/1508
550/1022
820/1508
550/1022
820/1508
550/1022
820/1508
550/1022
820/1508
Vacuum 2
2
1
2
2
°C/°F
820/1508
840/1544
820/1508
840/1544
820/1508
840/1544
820/1508
840/1544
820/1508
840/1544
Crystallization/Glaze HT/LT
IPS e.max CAD HT/LT with or without application of IPS e.max CAD Crystall./Glaze, Shades, Stains, and Add-On
Correction firing
with IPS e.max CAD Crystall./Glaze, Shades, Stains, or Add-On
Only the program memories 65-69 can be used with the Programat P100.
Furnace
P80
P100
P200
P300
P500
P700
PX1
EP 600
EP 3000
EP 5000
Closing time
S
min.
6:00
6:00
6:00
6:00
6:00
6:00
Stand-by
temperature
B
°C/°F
403/757
403/757
403/757
403/757
403/757
403/757
Heating rate
t
1
°C/°F/min.
–
90/162
90/162
90/162
90/162
90/162
Firing
temperature
T
1
°C/°F
–
820/1508
820/1508
820/1508
820/1508
820/1508
Holding time
H
1
min.
–
0:10
0:10
0:10
0:10
0:10
Heating rate
t
2
°C/°F/min
30/54
30/54
30/54
30/54
30/54
30/54
Firing
temperature
T
2
°C/°F
840/1544
840/1544
840/1544
840/1544
840/1544
840/1544
Holding time
H
2
min.
3:00
3:00
3:00
3:00
3:00
3:00
Long-term
cooling
L
°C/°F
700/1292
700/1292
700/1292
775/1427
1:30 min
700/1292
0:20 min
700/1292
700/1292
Cooling rate
t
l
°C/°F/min
–
–
0
–
–
0
Vacuum 1
1
1
1
2
°C/°F
–
550/1022
820/1508
550/1022
820/1508
550/1022
820/1508
550/1022
820/1508
550/1022
820/1508
Vacuum 2
2
1
2
2
°C/°F
550/1022
840/1544
820/1508
840/1544
820/1508
840/1544
820/1508
840/1544
820/1508
840/1544
820/1508
840/1544
Only the program memories 65-69 can be used with the Programat P100.