Ivoclar Vivadent IPS e.max CAD Labside User Manual
Page 52

2
nd
Dentin and Incisal firing (Corrective firing)
Compensate for the shrinkage and complete the missing areas.
Stain and Glaze firing
Stain firing is conducted with IPS e.max Ceram Essence and
IPS e.max Ceram Shades, while Glaze firing is carried out
with IPS e.max Ceram Glaze (powder, paste or spray).
Depending on the situation, the Stain and Glaze firings may
be conducted together or separately one after the other. The
firing parameters are identical.
Compensate for the shrinkage with Dentin, Transpa and Incisal materials
Completed, stained and glazed IPS e.max CAD MO restoration
Then the restoration is fired using the firing parameters for the 2
nd
Dentin and Incisal firing
52
Firing parameters for the 2
nd
Dentin and Incisal firing
IPS e.max Ceram on IPS e.max CAD
B
S
t
➚
T
H
V
1
V
2
Layering Technique
[°C/°F]
[min]
[°C/°F/min]
[°C/°F]
[min]
[°C/°F]
[°C/°F]
2
nd
Dentin and Incisal firing
403/757
4:00
50/90
750/1382
1:00
450/842
749/1380
Firing parameters for the Stain and Glaze firing
IPS e.max Ceram on IPS e.max CAD
B
S
t
➚
T
H
V
1
V
2
Layering Technique
[°C/°F]
[min]
[°C/°F/min]
[°C/°F]
[min]
[°C/°F]
[°C/°F]
Stain firing
403/757
6:00
60/108
725/1337
1:00
450/842
724/1335
Glaze firing
403/757
6:00
60/108
725/1337
1:00
450/842
724/1335