Hypertherm HTA Rev 6.00 Operators Manual User Manual
Page 184

170
Operator’s Manual
Save Data
Pressing the Save Data softkey allows the user to save the current process settings to the Hard
drive creating a custom user database based on the eight process variables selected.
Process Defaults
Pressing the Process Defaults softkey allows the user to reset the current settings to factory
recommend factory defaults based on the eight process variables selected.
Save Database
Pressing the Save Database softkey allows the user to save the current User and Factory
databases to diskette. User files are designated with a .usr file extension and the factory files are
designated with a .fac file extension
Examples of user and factory file names.
Mild Steel-HT4400-HD4070.usr
Mild Steel-HT4400-HD4070.fac
Load Database
Pressing the load Database softkey allows the user to the factory default database files which are
supplied by Hypertherm in a Text file ( .txt ), user files ( .usr ) or factory files ( .fac ) from diskette.
Factory text file names.
Mild Steel Cut Chart Data
mschart.txt
Aluminum Cut Chart Data
alchart.txt
Stainless Steel Cut Chart Data
sschart.txt
It is recommended that the Database be updated through the control rather than the Power
Supply if the serial communications link is enabled.
Test Preflow
Pressing the Test Preflow softkey performs the Test Preflow Gases feature at the Plasma supply.
Test Cutflow
Pressing the Test Cutflow softkey performs the Test Cutflow Gases feature at the Plasma supply.
Notes:
-
Please refer to the power supply operators manual for complete information on the operation
and setup of the Plasma supply.
-
A serial communications port for the Plasma supply must first be selected at the Port
configuration screen to be enable the feature for use.
-
The Plasma supply parameters must first be enabled in the password protected Station
Configuration screen to allow the Cut Chart Information for the Plasma supply to be available
for use.
-
Power Supplies equipped with the Integrated Command
®
THC may be used with the control
setups. The Command
®
THC must first be enabled for use in the password protected Station
Configuration Screen.