31

8.0 TROUBLESHOOTING

WARNING

UNPLUG THE POWER CORD BEFORE

REMOVING, ADJUSTING OR REPAIRING ANY

PARTS IN THE FD 280.


Trouble

Cause

Solution

1. Nothing works,

no orange Power
Indicator light

Power switch is not

on.

Turn power switch on.

Power cord is

damaged or not
plugged into proper
outlet.

Replace power cord if

damaged or plug into
proper outlet if
necessary.

Outlet does not have

power present.

Check circuit source

for a blown fuse or
circuit breaker.

2. Not tabbing --

TAB READY light
is on but no tabs
at peel point.

Tabs not threaded

correctly

Tab motor failure,
Microprocessor

Failure

Out of tabs or tab

sensor blocked

Check and re-thread.
Toggle Power Off and

on waiting 5-10
seconds to reset
processor.

Remove tabs from

the sensor if present
and re-thread.

3. Not Tabbing

Tab Ready Light
is OFF

Transport Failure
Tab Mode Switch

Inconsistent tab

length counts due to
slippage in transport,
jamming pieces.
Poor Feeding.

Tab Mode Switch on

Setup

Processor. Toggle

off and on to reset

4. FD 280 stops.

Power entry fuse is

blown.

Replace blown line

fuse. Refer to
Section 3.3.

FD 280 keeps blowing

fuses after you
replace them.

Contact authorized

Formax dealer.