beautypg.com

Power connection – Formax FD 280 User Manual

Page 12

background image

8

3. POWER CONNECTION

WARNING

BEFORE PLUGGING THE FD 280 INTO AN

OUTLET, CAREFULLY READ THE FOLLOWING

INFORMATION ABOUT VOLTAGES, FUSES AND

THE POWER CORD.

3.1 Safety

The FD 280 can connect to any power distribution
system, including the European IT Power System.
Because the European IT Power System does not
have a grounded neutral leg, the FD 280 uses
protective fusing in both the neutral and hot supply
lines of power.

WARNING

A BLOWN FUSE IN THE NEUTRAL LEG COULD

MEAN INTERIOR PARTS OF THE FD 280 REMAIN

AT A HAZARDOUS VOLTAGE. ALWAYS UNPLUG

THE POWER CORD BEFORE REMOVING COVERS

FROM THE FD 280.

3.2 Line Voltage

The FD 280 is rated for continuous operation using a
variety of supply voltages. Possible line voltages are
240V, 230V, 220V, 120V and 100V at 50 or 60 Hz.
The manufacturer configures the FD 280 to operate
with the voltage requested by the customer.

CAUTION

VERIFY THE CORRECT VOLTAGE
SETTING BEFORE PLUGGING THE FD 280
INTO AN OUTLET.


Read the current voltage setting through the
VOLTAGE SELECTOR WINDOW on the non-
operator side of the FD 280. (Refer to Figure 3.1.)
Use the following instructions to change the voltage
setting: