beautypg.com

Formax 2200 Series User Manual

Page 102

background image

Operator's Manua

l 2200 Series

1

02

No:

1

2

3

4

5

6

7

8

9

10

11

12

13

Possible Cause:

Thermal overload protection on
feeder has switched off

Round plug between feeder and
register table not plugged correctly

Thermal overload protection in
electrical compartment has switched
off

Photodetector 1 covered with paper
or dirty

Sensibility of photodetector 1 too
low

Photodetector 1 defective

Fold plate plug not connected
properly

Deflector mechanism jammed

Gear motor for adjustment of paper
stop is defective

Deflector jammed, does not return
to base position

Fold plate stop jammed
Display shows: 0000

Gear motor for adjustment of paper
stop jammed

Fold plate stop jammed

Remedy:

Remove front cover of flat pile feeder
(hexhead nut M13) and set thermal
overload protection to a higher value

Check connection

Open electrical compartment in fold
unit 1 (pull out drawer), set thermal
overload protection to higher value

Remove paper or clean photodetector

Change sensibility by turning potentio-
meter on photodetector: Red light in
LED must come on when a sheet
covers photodetector

Replace photodetector 1

Switch off main switch. Check plug of
fold plates for proper fit

Move fork to its base position

Replace gear motor

Clean bearing point, check deflector for
easy movement

Remove fold plate. Loosen Allen
screws (2.5 mm wrench) on idler gear
and manually move fold plate stop.
Then move fold plate stop back to base
position, all the way back, until deflec-
tor engages. Retighten Allen screws
(see Adjustment of Fold Plates)

Loosen mounting screws on gear motor
and set fold plate stop manually by
means of knurled screw

Switch off main switch and then on
again. Select correct fold plate depen-
ding on fold. Try to move fold plate
stop out of base position via minus-key
or by turning knurled screw