Digi-Star EZII Escape Computer Command Set User Manual
Page 8

EZII Escape Computer Command Set
8
D36 48 Rev G
November 30, 2009
Gu - Signon Message Command:
This command allows an alpha-numeric message (up to 40 characters in length) to be displayed on the
indicator during power up. It will appear immediately after a short “HELLO” message is displayed.
This command includes the following information:
Start new command:
Command identifier:
Gu
Start of Message:
Message:
Must be at least 1 character and can be up to 40 characters long. If the
message is less than six characters the value will appear on the right side of
the display. Valid characters may not be less than the Space " " (hex value
20) character and may not be greater than the "z" (hex value 7A) character of
the ASCII character set.
Note: The character "$" will show up as a "l" (small character L ) on the
indicator display since the "$" character is a special character used for
Lock-On weigh mode.
Note: Lower case characters will be printed as lower case characters however
they appear as UPPER case characters on the scale's display.
End of command:
Signon Message Command Response:
If the command is completed successfully, then the
after receiving the command. If the command fails, the
Signon Message Command Examples:
The following command string
message " DS" after “ HELLO” is displayed on the indicator when the unit is first turned on.
The command string
LOANER" after “ HELLO” is displayed on the indicator when the unit is first turned on.
GA - Select Scale Command:
This command is used to switch the indicator to display scale A, B, or C. This command includes the
following information:
Start new command:
Command identifier:
GA
Selected scale:
a = scale A, b = scale B, c = scale C
End of command:
Select Scale Command Example:
When the "Select Scale Command" string is sent to the indicator
the indicator will display the weight on Scale C and the
If the command fails, the