EZII Escape Computer Command Set
28
D36 48 Rev G
November 30, 2009
Direct Access Number Command:
D - Direct Access Number Command:
This computer interface command allows individual setup values of the Long and Short Form Setup &
Calibration to be changed. There are certain circumstances when the scale cannot process serial commands.
When the operator is reviewing recipes, operating the timer, displaying messages and while the operator is
using the Short or Long Form Setup & Calibration functions are some of the operations when the scale
cannot process Computer Interface Commands until that operation is completed.
This command includes the following information:
Start new command:
Command identifier:
D
Direct Access Number:
xxx, (must be 3 digits followed by a comma)
Data length:
yyy, (must be 3 digits followed by a comma)
Data format to send:
z (can be variable in length, but must match the D.A.N. selections)
End of command:
Direct Access Number Command Response:
If the command is completed successfully, then the command string shown below will return the
(Hex value 0x06) character. If the command fails, the
Note: Only D.A.N. #213 and 103 are supported at this time.
D.A.N. (xxx)
Length (yyy)
Data Format (z)
Data Selections
103
001
Letter
D = disable Motion, E = enable Motion
213
002
Numeric
Scoreboard Modes 00 - 26 (must be two digits).
Direct Access Number Command Examples:
The following command string:
section.
The following command string:
Data format examples are found in the section titled “Continuous Computer Status Data Output”.