Controlling a heat pump
Select cabling that is suitable for your heat pump or refer directly to the manufacturer's
specifications.
N
N
L
L
1
2
3
Controlling electric convectors
To control electrical convectors, you MUST
use a power contact switch that is suitable
for the total power to be controlled.
This power contactor switch must be fitted
into the electrical switchboard of your home.
- 8 -
Connecting a boiler without thermostat
input
If the boiler does not have a thermostat
input, you can directly control the circula-
tor which is located next to the boiler (the
pump enabling circulation of the hot water
into the radiators).
- Directly control the power supply to the
circulator using the thermostat.
N
L
1
2
3
thermostat
circulator
mains power
230 V/50 Hz
mains power
230 V/50 Hz
thermostat
power supply of
the contact
switch coil
contact switch (not supplied)
fitted in the electrical
switchboard
convector(s)
Heat pump
with thermostat input
and summer / winter Input
Heat pump
with thermostat heat input
and thermostat cool input
Heat pump
with thermostat input
and Summer / winter switch
Hydraulic kit
Hydraulic kit
Hydraulic kit
Underfloor
heating
output
Summer /
winter switch
Underfloor
heating
output
Underfloor
heating
output
Summer /
winter switch
Geothermal OR Air source
Geothermal OR Air source
Geothermal OR Air source
Thermostat
input
Thermostat
input
Summer /
winter switch
Summer /
winter Input
Thermostat
heat input
Commun
Thermostat
cool input
winter
Summer