5.2.20 RSTPASS
Syntax: rstpass [key=
The rstpass command is always available regardless of whether the console is logged in or not.
When invoked without any arguments, it will display unique identification about this particular
device. The user may then contact the manufacturer with that information to obtain the
When the rstpass command is entered with the key=
is reset to the original value of “initial”. If an invalid key is entered, a MINOR alarm is generated to
that effect.
5.2.21 TIMEOUT
Syntax: timeout [OFF |
For those users that wish the console to automatically log off after a period of inactivity, there is
the console timer. The console timer defaults to the disabled condition and may be activated by
the timeout command.
The command is only visible when the console is logged in. The
between 1 and 255 inclusive. When the module determines a period of inactivity of the specified
time, it shall automatically log off the console. An INFO level alarm is issued at that time.
5.2.22 LABEL
Syntax: label [ “Double Quoted String” | none ]
The
label
command is used to give the command console a unique prompt. The command is
visible only when logged into the UTM administrative console. If the
label
command is invoked
without arguments, the current configuration of the label is displayed. If the argument to the
label
command is the word ‘none’, any current label is set to a null value. If the argument to the
label
command is a double quoted string, the contents of the string becomes the application console
prompt label. A console label may be up to 31 characters in length.
5.2.23 HPIO
Syntax: HPIO RESET
ENABLE < ALL | FIBER | <10/100 PHY RANGE> >
DISABLE < ALL | FIBER | <10/100 PHY RANGE> >
AUTO < ALL | <10/100 PHY RANGE>
10HDX < ALL | <10/100 PHY RANGE>
10FDX < ALL | <10/100 PHY RANGE>
100HDX < ALL | <10/100 PHY RANGE>
100FDX < ALL | <10/100 PHY RANGE>