beautypg.com

Appendix a: optional temp sensor – Daktronics G-1000-34-R User Manual

Page 39

background image

Appendix A

A-1

Appendix A: Optional Temp Sensor

Electrical Installation

Reference Drawings:

System Riser Diagram (422) . . . . . . . . . . . . . . . Drawing A-88425
System Riser Diagram (Modem) . . . . . . . . . . . . Drawing A-88426
Power/Signal Termination Panel . . . . . . . . . . . . Drawing A-88427

A 4-conductor cable with shield is used to connect the temp sensor to the display. The cable is
terminated in the entrance enclosure on the terminal block labeled “TEMP SENSOR.”

TB42

Cable Wires

Temperature Sensor

Pin 7

Green

(Temp RX-P)

Pin 8

White

(Temp RX-N)

Pin 9

Red

(Temp +5V)

Pin 10

Black

(Temp GND)

Pin 10

Bare

N/A

If the display is two sided, only one temp sensor is used for both. An extra piece of the 4-
conductor cable must be used to jumper the temp sensor data to the second sign. Refer to
Drawings A-88425, A-88426, A-88427 (all in Section 3) for connections. L Note: DO NOT