beautypg.com

Daktronics CE-1010 User Manual

Page 62

background image

6/30/2004
ED-14413
Page 1

Signal Converters and Loop-back Testing
for Direct Connections

The following table gives the typical state of the signal converter when the LEDs are either on
or off. Refer to

Figure 1

and

Figure 2

on next the page for an illustration of the signal

converters and the locations of the various components.

LED

Indicators

Typical States

Troubleshooting

ON

Signal Converter (SC) is receiving
power

SC is not receiving power

Check power/Replace fuse

Power

OFF

Internal 1 AMP fuse is bad

Replace fuse

SC is not connected to a serial port

Connect to open computer
COM port (COM port could be
sleep mode.)

On Steady

1. Serial port or serial cable is bad
2. Computer COM port is in sleep

mode

1. Try another port or replace

serial cable

2. Communicate with display

OFF Steady

Normal state, SC is not transmitting
data

TX

Brief Flicker

SC is transmitting data

ON Steady

1. Field cabling between SC and display

is bad


2. Is connected to display output jack or

terminated incorrectly


3. Bad COM port is on display controller

1. Eliminate cabling by

disconnecting wire/cable
from SC to display controller

2. Check connections and

terminations

3. Eliminate by disconnecting

wire/cable to display
controller

OFF Steady

Normal state, SC is not receiving data

RX

Brief Flicker

SC is receiving data

TX/RX

ON Steady

(If serial cable is connected) Bad SC

Replace SC