Section 2: mechanical installation, 1 mechanical installation overview, Section 2 – Daktronics DataTime Outdoor LED Time & Temperature Displays User Manual

Page 7: Mechanical installation, Mechanical installation overview

background image

Section 2:

Mechanical Installation

Daktronics does not guarantee the warranty when the display is not constantly in a stable

environment.

Daktronics' engineering staff must approve any changes that may affect the display's weather-

tightness. If any modifications are made, detailed drawings of the changes must be submitted to

Daktronics for evaluation and approval or the warranty may be void.

Daktronics is not responsible for the installation or the structural integrity of support structures

done by others. It is the customer’s responsibility to ensure that a qualified structural engineer

approves the structure and any additional hardware.

2.1 Mechanical Installation Overview

Mechanical installation typically consists of mounting the display and any accompanying

panels to the support structure.

The table below shows the weights and dimensions for each model in this series.

Model

Dimensions
(H x W x D)

Weight
Uncrated

Digit Size

DF-1010-10

1’-3” x 3’-0” x 6”

(380 mm, 910 mm, 152 mm)

30 lb

14 kg

10”

(254 mm)

DF-1010-13

1’-6" x 4’-0" x 6"

(457 mm, 1,219 mm, 152 mm)

35 lb

16 kg

13"

(330 mm)

DF-1010-18

2’-0" x 5’-0" x 6"

(610 mm, 1,524 mm, 152 mm)

60 lb

27 kg

18"

(457 mm)

DF-1010-24

2’-6" x 6’-0" x 6"

(762 mm, 1,829 mm, 152 mm)

90 lb

41 kg

24"

(610 mm)

DF-1011-10

1’-3” x 3’0” x 6 1/8”

(381 mm, 914mm, 155 mm)

25 lb

12 kg

10”

(254 mm)

DF-1011-13

1’-6” x 4’-0” x 6 1/8”

(457 mm, 1,219 mm, 155 mm)

35 lb

16 kg

13”

(330 mm)

DF-1011-18

2’-0” x 5’-0” x 6 1/8”

(610 mm, 1,524 mm, 155 mm)

60 lb

27 kg

18”

(457 mm)

DF-1011-24

2’-6” x 6’-6” x 6 1/8”

(762 mm, 1,981 mm, 155 mm)

90 lb

41 kg

24”

(610 mm)

Mechanical Installation

3