Connection from Sensor to the Display Driver

If the distance from the temperature sensor to the display is greater than the provided 25 foot

(7.6 m) cable, a 4-conductor shielded cable can be connected from the sensor to TB1 on the

display driver board.

1. The display's power must be OFF when attaching the internal sensor cable to the host

driver.

2. Connect the temperature sensor to the terminal block (TB1) on the host driver. Refer

to Figure 7 and the table below for the correct connections.

Figure 7: Temperature Sensor to Display Driver Connections

CAN Temperature Sensor (TB1) Field Cabling MASC Driver to CAN

Pin 1 (+5V CAN)

Red

Pin 2 (+5V CAN)

Pin 2 (CAN H)

Green

Pin 4 (CAN H)

Pin 3 (CAN L)

White

Pin 5 (CAN L)

Pin 4 (GND CAN)

Black

Pin 3 (GND CAN)

Shield

Pin 3 (Shield)