Section 3:

Electrical Installation

Daktronics outdoor displays are ETL and UL listed and tested to CSA standards for outdoor use.

Contact Daktronics with questions regarding the testing procedures.

Only qualified individuals should perform power routing and termination to the display. It is the

responsibility of the electrical contractor to ensure that all electrical work meets or exceeds local and

national codes.

3.1 Preparing for Power/Signal Connection

Reference Drawing:

Time & Temp Power/Signal Hookup ...................................................... Drawing A-938369

Electrical installation consists of the following process:

Providing power and ground to a disconnect near the display.

Routing power and ground from the main disconnect to the display driver/power

enclosure.

Connecting the display ground to a grounding electrode at the display location.

Routing the control signal cable from the control location to the display location.

Drawing A-938369 provides detailed instructions for power and signal connections for time

and temperature displays, including connection of the temperature sensor and connections

between host and client displays. Refer to this drawing before completing any part of the

electrical installation.

3.2 Power and Grounding Connections

Power

Correct power installation is imperative for proper display operation. The following

subsections detail display power installation. Only qualified individuals should complete

electrical installation. Improper installation could result in serious damage to the equipment

and be hazardous to personnel.

Daktronics DataTime displays have removable or hinged front panels that allow access to the

digits, cabling, and other electronic components. Power and control signal hookup has been

simplified.

DataTime outdoor displays require a dedicated, 120 V circuit for incoming power. The

display itself has no breakers or fuses.

WARNING: The display circuit must be fused at 15 A, and all conductors must be

designed to pass a 15 A current in normal operation. Failure to meet wiring and over

current protection device requirements is a violation of the National Electrical Code and

will void the display's warranty.

Electrical Installation

9