Some multiple-module DataTime displays use
“host/client” displays, which do not contain a driver
and may use either client or host digit outputs. The DF-
1011 model uses the host/client configuration.
Address Settings
The address of each driver is set using an eight-position
DIP-switch (S1), and the address is based on that driver’s
position in the display system. If a single-line display is
used, the address will typically be Address “01.” This
means that switch 1 is turned “ON” and the remaining 7
switches are in the “OFF” position. This is the default
address set when each display is shipped. In multiple-
product displays, the address determines which line of
information is shown on the driver’s digits. The switch is
set using a binary address. Use the table and the
examples in Figure 12 for setting the address.
Note: Some older drivers set the address of each driver
using an address plug (Daktronics part # 0A-1150-0122)
in J19. The address, either using a switch or a plug, needs
to be set for each driver.
Figure 12: Common Address Settings
Binary Address Settings
Address
Switch Number
1
2
3
4
5
6
7
8
1
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
2
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
3
ON
ON
OFF
OFF
OFF
OFF
OFF
OFF
4
OFF
OFF
ON
OFF
OFF
OFF
OFF
OFF
5
ON
OFF
ON
OFF
OFF
OFF
OFF
OFF
6
OFF
ON
ON
OFF
OFF
OFF
OFF
OFF
7
ON
ON
ON
OFF
OFF
OFF
OFF
OFF
8
OFF
OFF
OFF
ON
OFF
OFF
OFF
OFF
9
ON
OFF
OFF
ON
OFF
OFF
OFF
OFF
10
OFF
ON
OFF
ON
OFF
OFF
OFF
OFF
11
ON
ON
OFF
ON
OFF
OFF
OFF
OFF
12
OFF
OFF
ON
ON
OFF
OFF
OFF
OFF
13
ON
OFF
ON
ON
OFF
OFF
OFF
OFF
14
OFF
ON
ON
ON
OFF
OFF
OFF
OFF
15
ON
ON
ON
ON
OFF
OFF
OFF
OFF
16
Electrical Installation