Some multiple-module DataTime displays use

“host/client” displays, which do not contain a driver

and may use either client or host digit outputs. The DF-

1011 model uses the host/client configuration.

Address Settings

The address of each driver is set using an eight-position

DIP-switch (S1), and the address is based on that driver’s

position in the display system. If a single-line display is

used, the address will typically be Address “01.” This

means that switch 1 is turned “ON” and the remaining 7

switches are in the “OFF” position. This is the default

address set when each display is shipped. In multiple-

product displays, the address determines which line of

information is shown on the driver’s digits. The switch is

set using a binary address. Use the table and the

examples in Figure 12 for setting the address.

Note: Some older drivers set the address of each driver

using an address plug (Daktronics part # 0A-1150-0122)

in J19. The address, either using a switch or a plug, needs

to be set for each driver.

Figure 12: Common Address Settings

Binary Address Settings

Address

Switch Number

1

2

3

4

5

6

7

8

1

ON

OFF

OFF

OFF

OFF

OFF

OFF

OFF

2

OFF

ON

OFF

OFF

OFF

OFF

OFF

OFF

3

ON

ON

OFF

OFF

OFF

OFF

OFF

OFF

4

OFF

OFF

ON

OFF

OFF

OFF

OFF

OFF

5

ON

OFF

ON

OFF

OFF

OFF

OFF

OFF

6

OFF

ON

ON

OFF

OFF

OFF

OFF

OFF

7

ON

ON

ON

OFF

OFF

OFF

OFF

OFF

8

OFF

OFF

OFF

ON

OFF

OFF

OFF

OFF

9

ON

OFF

OFF

ON

OFF

OFF

OFF

OFF

10

OFF

ON

OFF

ON

OFF

OFF

OFF

OFF

11

ON

ON

OFF

ON

OFF

OFF

OFF

OFF

12

OFF

OFF

ON

ON

OFF

OFF

OFF

OFF

13

ON

OFF

ON

ON

OFF

OFF

OFF

OFF

14

OFF

ON

ON

ON

OFF

OFF

OFF

OFF

15

ON

ON

ON

ON

OFF

OFF

OFF

OFF

16

Electrical Installation