Electrical Installation

11

5. Mount the temperature sensor as described in Section 2.4, and connect the quick-connect cable to the

four-pin quick connect on the back of the display.

6. The DataMaster controller plugs into the J box using a DB9M to DB9F serial cable.

Direct – Indoor Connection

Reference Drawings:

Riser Diagram, Indoor Wire Control ........................................................

Drawing A-175342

Time & Temp Power/Signal Hookup .......................................................

Drawing A-938369

Enclosed Driver, 4 Column .....................................................................

Drawing A-938300

A direct-controlled display can also be used from a J box at in indoor location. In that case, only two, 22
AWG, signal wires will need to be connected to the J box and a wall pack transformer will be used for power
to the DataMaster controller. The distance from the indoor J box to the host driver can be up to 2,000 ft (600
m). Refer to

Figure 11 and Drawing A-175342 for system layout and signal connections.

1. Mount the J box at an indoor location.

2. Select the host driver by inserting the Protocol-4 plug into the five-pin protocol jack (J20).

3. Route a four-conductor, 18 AWG, shielded signal cable through conduit from the J box to the driver

enclosure in the host display.

Wiring from J-Box to Host Driver Enclosure
J-Box Pin Number Cable Color Enclosure Terminal Block

Pin 1

Red

12 V DC Out (+)

Pin 5

Black

12 V DC Out (-)

Pin 5

White

Signal IN (-)

Pin 6

Green

Signal IN (+)

Pin 8

Brown

Signal OUT (+)

Pin 9

Blue

Signal OUT (-)