Error Number Cause

Display

Reset/Remedy

24: Incline

moving

too slowly

Incline is commanded to

move, yet the change in

feedback is slower than the

minimum allowed.

None, stored error

only

Inspect and lubricate the

lead screw.

Re-calibrate the incline.

Measure the incline

potentiometer output.

The potentiometer

could be ‘bad’.

Replace the battery.

25: Incline

movement

feedback

stopped

Incline is commanded to

move yet the feedback

indicates the value is not

changing or ceases to

change as expected.

Dashes shown in

incline window.

Display attempts to

re-calibrate incline

position on entry to

Dormant Mode.

26: Incline

disabled

Incline feedback problems

could not be remedied by

re-calibrating after an Error

25.

Dashes shown in

incline window.

Incline is disabled.

Contact service

technician.

27: Low

Battery

Battery voltage is reported

to be below the limit of

10.7v DC and the controller

has issued the low battery

warning.

Dashes shown in

incline window.

Incline is disabled.

Further use will re-

charge the battery

and the error condition

will be cleared

automatically.