beautypg.com

End character, Negative responses, 6 end character 3.1.7 negative responses – Comtech EF Data KP-10 User Manual

Page 28

background image

KP-10 External Keypad

Revision 1

Operation

MN/KP10.IOM

18

CAUTION

Do not use any global address when accessing the RSU unit with the KP-10.

3.1.6 E

ND

C

HARACTER

As stated previously, each message on the remote link begins with a start character and
ends with an end character

.

The start and end characters are different for commands and

responses.

The end characters are as follows:

!

Commands “cr”] (carriage

return and end bracket)

!

Responses

] (end bracket)

3.1.7 N

EGATIVE

R

ESPONSES

If the terminal receives a message which does not match the established protocol or
cannot be implemented, a negative acknowledgment is sent in response.

Examples of negative responses include:

!

>add/?ER1_PARITY ERROR'cr''lf']

(Error message for received parity errors.)

!

>add/?ER2_INVALID PARAMETER'cr''lf']

(Error message for a recognized command which cannot be implemented or has
parameters which are out of range.)

!

>add/?ER3_UNRECOGNIZABLE COMMAND'cr''lf']

(Error message for unrecognizable command or bad command syntax.)

!

>add/?ER4_CONVERTER IN LOCK MODE'cr''lf']

(Controller in Lock mode, must go to Enable mode first.)

!

>add/?ER5_NOT SUPPORTED BY HARDWARE'cr''lf']

(The command is a legal command, but is not supported by the current hardware
configuration.)