Remote Control Operation
RSU-503 Redundancy Switch Unit
B–8
Rev. 8
Redundancy
Fault Status
Command
:
Response:
XVA_XXX'cr'
XVB_XXX'cr'
P05_XXX'cr'
P32_XXX'cr'
ULA_XXX'cr'
ULB_XXX'cr'
ULS_XXX'cr'
DLA_XXX'cr'
DLB_XXX'cr'
DLS_XXX'cr''lf']
Where:
XXX = OK or FLT. Input power from Unit A.
XXX = OK or FLT. Input power from Unit B.
XXX = OK or FLT. Internal +5V power.
XXX = OK or FLT. Internal +32V power.
XXX = OK or FLT. Uplink fault on Unit A.
XXX = OK or FLT. Uplink fault on Unit B.
XXX = OK or FLT. Uplink switch ambiguity.
XXX = OK or FLT. Downlink fault on Unit A.
XXX = OK or FLT. Downlink fault on Unit B.
XXX = OK or FLT. Downlink switch ambiguity.
This command returns a block of data reflecting the current and
logged faults in the switch. Logged faults will be reset when
receiving this command, while current faults can be read on the
second request.
Redundancy
Summary Fault
Command
:
Response:
Where: XXX = OK or FLT.
Returns status of current faults only.
Redundancy
Maintenance
Status
Command
:
Response:
XVA_nn.n'cr'
XVB_nn.n'cr'
P05_nn.n'cr'
P32_nn.n'cr''lf']
Where:
nn.n = Voltage of input power A.
nn.n = Voltage of input power B.
nn.n = Internal +5V power supply.
nn.n = Internal +32V power supply.
This command returns a block of data from the switch, reflecting
the status of certain internal parameters for the purpose of
troubleshooting.
RS232 Baud
Rate Select
Command
:
Response:
Status:
Response:
Where: XXXX = 300 to 19200, in standard settings of 300, 600,
1200, 2400, 4800, 9600, and 19200. Default = 9600.
RS232 Parity
Select
Command
:
Response:
Status:
Response:
Where: XX = OD (odd), EV (even), or NO (none, for 8 bit).
Default = EV.
Equipment
Type Status
Command
:
Response:
R - RSU-503 SW_X.XX'cr'
A - RFT SW_X.XX'cr'
B - RFT SW_X.XX'cr''lf']
Where: X.XX = software version.
This command returns the equipment type polled and software
version of each unit in the redundant system.
If unit A and/or B is not communicating with the switch, the
following response(s) will be displayed:
A - NO COMMUNICATION'cr'
B - NO COMMUNICATION'cr''lf']