Page 47

Maintenance
RSU-503 Redundancy Switch Unit
4–2
Rev. 8
4.2 Internal Indicators
The switch does not have any external indicators. The internal indicators (shown in
Figure 4-1) are not normally used by the operator. However, if the switch must be
opened, descriptions of the indicators are provided in the following table.
Indicator
LED
Cause
System Status
PWR A
Green
Illuminates if RFT A power is available.
PWR B
Green
Illuminates if RFT B power is available.
32V
Green
Illuminates when power available to switches.
SUM FLT
Red
Illuminates an ambiguity failure, RFT fault, or power supply
fault.
Uplink
FLT A
Red
Illuminates with failure of unit A uplink.
FLT B
Red
Illuminates with failure of unit B uplink.
FLT AMB
Red
Illuminates if uplink switch indicators do not agree.
B OL
Yellow
Illuminates when unit B uplink is online.
MAN
Yellow
Illuminates when uplink is in manual mode.
Downlink
FLT A
Red
Illuminates with failure of unit A downlink.
FLT B
Red
Illuminates with failure of unit B downlink.
FLT AMB
Red
Illuminates if downlink switch indicators do not agree.
B OL
Yellow
Illuminates when unit B downlink is online.
MAN
Yellow
Illuminates when downlink is in manual mode.
Figure 4-1. LED and Switch Locations