Front Panel Operation

CRS-200 Redundancy Switch

7–10

Rev. 1

7.1.4.3 (INFO)

IF-SWITCH

TRANSPONDER SWITCH IS

ABSENT

This screen shows whether a CRS-280 IF Transponder Switch is connected to the CRS-
200 1:N Redundancy Switch. When an IF switch is present, the second line will indicate
“PRESENT”, and any offline modem (TM or RM) will not have its Transmit IF muted by
the CRS-200.

7.1.4.4

(INFO) REMCONT (Remote Control Info)

REM CNTL: ON RS485-4W
ADDRESS: 5000 19200 BAUD

This screen shows if the unit is in LOCAL or REMOTE mode, and gives details of the
electrical interface type selected, the unit’s address, and the baud rate selected. Pressing
ENTER takes the user back to the previous menu.

7.1.4.5

(INFO) MASK (Alarm Mask Info)

ALARMS MASKED: MODEM-TX
MODEM-RX b bPSU-A PSU-B` `

This screen shows which alarms are currently masked. If an alarm is not masked, a blank
is displayed in the relevant screen position. Power Supplies A and B cannot be masked at
the same time, but are shown together here to indicate their relative positions.