CRS-200 Redundancy Switch
Front Panel Operation
Rev. 1
7–7
7.1.3.10
(CONFIG) REMOTE CONTROL
SELECT REMOTE CONTROL:
LOCAL REMOTE (PRESS ENT)
The user is prompted to select LOCAL or REMOTE using the LEFT/RIGHT arrow keys,
then to press ENTER.
7.1.3.11 (CONFIG,
REM-CNTL)
If LOCAL is selected then remote control will be disabled. Remote monitoring is still
possible.
7.1.3.12 (CONFIG,
REM-CNTL)
If REMOTE is selected then the following sub-menus will be displayed:
REMOTE CONTROL: BAUDRATE
INTERFACE (PRESS ENTER)
The user is prompted to select BAUDRATE or INTERFACE, using the LEFT/RIGHT
arrow keys, then to press ENTER.
7.1.3.13
(CONFIG, REM, BAUD)
EDIT LOCAL BUS BAUDRATE:
19200 BAUD (PRESS ENTER)
If BAUD RATE is selected:
The user is prompted to edit the baud rate of the remote control bus, connected locally to
the M&C computer. The value is changed using the UP/DOWN arrow keys. The user
should then press ENTER. Values of 300, 1200, 2400, 4800, 9600 and 19200 baud are
possible. Note that the asynchronous character format is FIXED at 8 data bits, 1 stop bit,
no parity (8-1-N).