CRS-200 Redundancy Switch

Front Panel Operation

Rev. 1

7–7

7.1.3.10

(CONFIG) REMOTE CONTROL

SELECT REMOTE CONTROL:
LOCAL REMOTE (PRESS ENT)

The user is prompted to select LOCAL or REMOTE using the LEFT/RIGHT arrow keys,
then to press ENTER.

7.1.3.11 (CONFIG,

REM-CNTL)

If LOCAL is selected then remote control will be disabled. Remote monitoring is still
possible.

7.1.3.12 (CONFIG,

REM-CNTL)

If REMOTE is selected then the following sub-menus will be displayed:

REMOTE CONTROL: BAUDRATE
INTERFACE (PRESS ENTER)

The user is prompted to select BAUDRATE or INTERFACE, using the LEFT/RIGHT
arrow keys, then to press ENTER.

7.1.3.13

(CONFIG, REM, BAUD)

EDIT LOCAL BUS BAUDRATE:
19200 BAUD (PRESS ENTER)

If BAUD RATE is selected:

The user is prompted to edit the baud rate of the remote control bus, connected locally to
the M&C computer. The value is changed using the UP/DOWN arrow keys. The user
should then press ENTER. Values of 300, 1200, 2400, 4800, 9600 and 19200 baud are
possible. Note that the asynchronous character format is FIXED at 8 data bits, 1 stop bit,
no parity (8-1-N).