1:1 Redundancy Switch

Revision 3

Summary Of Specifications MN/CRS120.IOM

5–4

5.2 1:1

Latching

Operation

Table 5-3 explains two cases and how the health of 1:1 subsystem is monitored.

Event

Mod A

Mod B

RF

Relay

Comments

Notes

Case 1

1 OK

(Online)

OK

(Standby)

A

The online and standby units are designated. Tx IF = A

1, 2, 7, 8

2 Fault OK B

A Faults and B is OK, switches to B. Tx IF = B

3, 4, 9, 10

3 Fault Fault B

Fault in A and B. Tx IF = None (carriers muted by both modulators).

3, 4, 9, 10

4 OK Fault B

Requires intervention. Tx IF = None (A is Standby and B carrier is
muted by modulator).

3, 4, 9, 10

5 OK OK B

Requires intervention. Tx IF = B.

3, 4, 9, 10

Case 2

6 OK

(Online)

OK

(Standby)

A

The online and standby units are designated. Tx IF = A

1, 2, 7, 8

7 OK Fault A

A is OK and B Faults. Tx IF = A.

1, 2, 5, 6,

11, 12

8 Fault Fault A

Fault in A and B. Switchover to a failed unit is not allowed. Tx IF =
None, and both carriers are muted.

1, 2, 5, 6,

11, 12

Notes:

Removal of the Alarm Cable while power is ON to both modulators:

1. Disconnecting the cable at A switches the B unit online and an alarm is reported.

Reconnecting the cable at A maintains the B unit online.

2. Disconnecting the cable at B keeps A online and an alarm is reported.

Reconnecting the cable to B keeps A online.

3. Disconnecting the cable at A maintains the B unit online and an alarm is reported.

Reconnecting the cable to A maintains the B unit online.

4. Disconnecting the cable at B maintains B online and an alarm is reported.

Reconnecting the cable to B keeps B online.

5. Disconnecting the cable at A maintains the A unit online and an alarm is reported.

Reconnecting the cable at A maintains the A unit online.

6.

Disconnecting the cable at B keeps A online and an alarm is reported.
Reconnecting the cable to B keeps A online.