Crs-120l summary of specifications, 2 crs-120l summary of specifications – Comtech EF Data CRS-120 User Manual
Page 39

1:1 Redundancy Switch
Revision 3
Summary Of Specifications MN/CRS120.IOM
5–3
5.1.2 CRS-120L Summary of Specifications
Table 5-2. CRS-120L Summary of Specifications
Description
Requirements
Equipment Type
1:1 Redundancy Switch
Modulators Supported
CDM-710 Satellite Modulator (L-Band)
Operating Modes
Fully automatic
Manual (via the front panel of the Online Modulator, or via the Modulator’s
remote control interface )
Architecture
Continuous fault comparison of Online and Standby units.
Switchover only to an unfaulted unit
Switch Conditions
Switchover initiated following: Unit faults or loss of Tx Traffic
Fault detection time
0.5 seconds maximum (time to detect a fault)
Switchover time
Within 0.5 seconds of fault detection (time for relay to switch)
IF Frequency Range
950 - 1750 MHz
IF Impedance
50
Ω
IF Connectors
SMA female
Return Loss
18 dB minimum from Tx-Online to the online Tx-A or Tx-B
Tx Insertion Loss
1.9 dB maximum, Tx-A or Tx-B to Tx-Online in low isolation position
1.9 dB maximum Tx-A or Tx-B to the Tx-Standby in low isolation position
Tx Sample
-20 dB typical below Tx-Online signal
Tx Isolation
45 dB minimum Tx-A or Tx-B to Tx-Online in the high isolation position
45 dB minimum Tx-A or Tx-B to Tx-Standby in the high isolation position
Indicator Contacts
9 pin D female connector with Form-C contacts indicating A or B is Online
Contacts are 30 VDC at 1 Amp maximum
Indicator LED
Two Green LEDs one indicates A Online the other indicates B Online
De-Energized State
With no power applied A is Online
Synchronization
The Standby absorbs the configuration of the Online unit (1:1 mode enabled)
Weight
1.1 lbs (0.5 kg)
Dimensions
1.7H x 8.15W x 5.57D inches
(4.3H x 20.7W x 14.1D cm)
See Section 1 for dimensional outline drawings.
Power requirements
1.2 Watts maximum
+ 12 volts DC @ 100 mA (max)
(Power is supplied by the Online and Standby Modulators, and the unit
current shares when both an ‘A’ and ‘B’ unit are present. These power
supplies are electronically fused and protected.)
A single modulator has capacity to source the required current.
Agency Approvals
CE: emissions, susceptibility and safety