beautypg.com

Crs-120 summary of specifications, 1 crs-120 summary of specifications – Comtech EF Data CRS-120 User Manual

Page 38

background image

1:1 Redundancy Switch

Revision 3

Summary Of Specifications MN/CRS120.IOM

5–2

5.1.1 CRS-120 Summary of Specifications

Table 5-1. CRS-120 Summary of Specifications

Description

Requirements

Equipment Type

1:1 Redundancy Switch

Modulators Supported

CDM-710 Satellite Modulator (70/140 MHz)

Operating Modes

Fully automatic
Manual (via the front panel of the Online Modulator, or via the Modulator’s
remote control interface )

Architecture

Continuous fault comparison of Online and Standby units.
Switchover only to an unfaulted unit

Switch Conditions

Switchover initiated following: Unit faults or loss of Tx Traffic

Fault detection time

0.5 seconds maximum (time to detect a fault)

Switchover time

Within 0.5 seconds of fault detection (time for relay to switch)

IF Frequency Range

52 - 176 MHz
(works with both 70 and 140 MHz Modulator IF options)

IF Impedance

75

IF Connectors

BNC female

Return Loss

18 dB minimum from Tx-Online to the online Tx-A or Tx-B

Tx Insertion Loss

1.0 dB maximum, Tx-A or Tx-B to Tx-Online in low isolation position
1.0 dB maximum Tx-A or Tx-B to the Tx-Standby in low isolation position

Tx Sample

-20 dB typical below Tx-Online signal

Tx Isolation

45 dB minimum Tx-A or Tx-B to Tx-Online in the high isolation position
45 dB minimum Tx-A or Tx-B to Tx-Standby in the high isolation position

Indicator Contacts

9 pin D female connector with Form-C contacts indicating A or B is Online
Contacts are 30 VDC at 1 Amp maximum

Indicator LED

Two Green LEDs one indicates A Online the other indicates
B Online

De-Energized State

With no power applied A is Online

Synchronization

The Standby absorbs the configuration of the Online unit
(1:1 mode enabled)

Weight

1.1 lbs (0.5 kg)

Dimensions

1.7H x 7.64W x 4.11D inches
(4.3H x 19.4W x 10.4D cm)
See Section 1 for dimensional outline drawings.

Power requirements

1.2 Watts maximum
+ 12 volts DC @ 100 mA (max)

(Power is supplied by the Online and Standby Modulators, and the unit
current shares when both an ‘A’ and ‘B’ unit are present. These power
supplies are electronically fused and protected.)
A single modulator has capacity to source the required current.

Agency Approvals

CE: emissions, susceptibility and safety