Crs-120l only. sma connectors j3, j4, j5, j6a, j6b, Standby tx if out switch, 5 standby tx if out switch – Comtech EF Data CRS-120 User Manual
Page 31

1:1 Redundancy Switch
Revision 3
Connector Pinouts
MN/CRS120.IOM
3–3
3.1.3 CRS-120 Only. TX-IF Connectors, J3, J4, J5, J6A, J6B
Ref Des
Name
Function
J3
Tx IF MON
-20 dB
Output, monitors online carrier at
approximately –20 dB.
J4
Tx IF Online
Output, Online Carrier
J5
Tx IF Standby
Output, Standby Carrier
J6A
Tx IF A
IF Input from Modulator A,
J6B
Tx IF B
IF Input from Modulator B
3.1.4 CRS-120L only. SMA Connectors J3, J4, J5, J6A, J6B
Ref Des
Name
Function
J3
-20 dB MON
Output, monitors online carrier at
approximately –20 dB.
J4 Online
Output,
Online
Carrier
J5
Standby
Output, Standby Carrier
J6A
Tx IF A
Input from Modulator A,
J6B
Tx IF B
Input from Modulator B
3.1.5 Standby TX IF Out Switch
The switch is a 2-position Dip switch. This switch enables or disables the standby Tx Carrier
provided there is no fault that will normally disable the carrier.
A
B
↑ (up position) Standby Tx carrier remains On
↓ (down position) Standby Tx carrier is forced Off.