9burst control mode, 9 burst control mode – Comtech EF Data KST-2000L User Manual
Page 74
Satellite Terminal System
Revision 2
Terminal Mode Commands
MN/KST2000L.IOM
7–10
ADAP
2 and 4 Watt SSPA
Stored Faults
Command
Response
RF_yyy'cr'
HPA_xxx'cr'
BV1_xxx'cr'
+9.75V_xxx'cr'
-5V_xxx'cr'
PROG_xxx'cr''lf']
Where yyy = ON or OFF, xxx = OK or FLT, BV1 = bias voltage
#1, PROG = inter processor communications, # = stored fault
location (0 to 9)
LNB
Stored Faults
Command
Response
LNA_xxx'cr''lf]'
Where xxx = OK or FLT, # = stored fault location (0 to 9)
AGC
Stored Faults
Command
Response
EIP_xxx'cr'
IIP_xxx'cr'
LOOP_xxx'cr''lf']
Where xxx = OK or FLT, # = stored fault location (0 to 9), EIP =
excessive input power, IIP = insufficient input power, LOOP =
loop converge
Common Equipment
Stored Faults
Command
Response
M&C_xxx'cr'
-7V_xxx'cr'
+7V_xxx'cr'
+12V_xxx'cr'
+17V_xxx'cr'
SFLT_#’cr ''lf']
Where xxx = OK or FLT, # = stored fault location (0 to 9), TXS =
transmit redundancy switch, RXS = receive redundancy switch, IF
= IF redundancy switch, RFLC = redundancy fault line cable
7.9
Burst
Control
Mode
Burst Control Mode
Command
Response
Status
Response:
where: xxx = (ON/OFF), default is OFF.
This command enters a special burst signal operation mode, when
Uplink AGC is disabled. The detected loss of an IF input carrier
will cause the uplink to turn its RF OFF. When the IF carrier is re-
applied, the RF will be turned ON
.