beautypg.com

Monitor and control (m&c), 2 monitor and control (m&c) – Comtech EF Data KST-2000L User Manual

Page 42

background image

Satellite Terminal System

Revision 2

Operation

MN/KST2000L.IOM

6. The system is ready for final installation to the antenna feed. Perform the rest of

the system alignment to applicable international, national, or local regulations.

4.2

Monitor and Control (M&C)

The Monitor and Control (M&C) monitors the KST-2000L and provides configuration
updates to the up converter, down converter, and HPA when necessary. Refer to
Figure 4-2.

EXT

OUTPUT

FAULT

RELAY

EXT

INPUT

LED

ROM

RAM

232 / 422

10 MHz
OCVCXO

72 Mhz
Generator

10 Mhz
Output

485

Module
COMM

M & C

Analog
MON

RAM

LNB
CTL

I C

2

Figure 4-2. Monitor and Control (M&C) Block Diagram


The KST-2000L configuration parameters are maintained on battery locked RAM, which
provides recovery after power down.

The M&C functions include extensive fault and status reporting. All KST-2000L func-
tions are accessible through the remote communications interface.

The M&C is composed of the following sections:

• Microcontroller and UART

• D to A and A to D converters

• ROM

• RAM

• Fault relays

• 10 MHz/72MHz Oscillators

• LNB power control

• Inter-module communication interface

The microcontroller is an Intel 80C32 operating at 16 MHz. The micro-controller con-
tains 256 bytes of internal RAM. The external ROM is 29F020 (256 kbytes). The battery
backed RAM is 8 kbytes in size.

The non-volatile RAM allows the KST-2000L to retain configuration information with-
out prime power for 1 year.