Comtech EF Data KST-2000L User Manual
Page 25
Satellite Terminal System
Revision 2
Summary of Specifications
MN/KST2000L.IOM
Table 2-5. M&C Functions/Parameters
Pin
Signal
Description
A
-TX/-RX or –TX only (see Notes)
-EIA-485 TX/RX or -EIA-422 TX
B
-TX/-RX or –RX only (see Notes)
-EIA-485 TX/RX or -EIA-422 TX
C
+TX/+RX or +TX only (see Notes)
+EIA-485 TX/RX or +EIA-422 TX
D
+TX/+RX or +RX only (see Notes)
+EIA-485 TX/RX or +EIA-422 TX
E
RXD
EIA-232 RX Data
F
RTS
EIA-232 Ready-to-Send (tied to CTS)
G
TXD
EIA-232 TX Data
H
DSR
EIA-232 Data Set Ready
J GND
Ground
K
LNA Power
+15 VDC to LNA
L
LNA Power Return
+15 VDC Return from LNA
M
RESET
Reset (momentary low resets system)
N GND
Ground
P
CTS
EIA-232 Clear-to-Send (tied to RTS)
R GND
Ground
S
+12V (KP10 Power)
KP10 Power Supply Output
T
2/4 WIRE (SEE note)
EIA-485/EIA-232 Operation Selection
U
UL_FLT_NC
Uplink Fault Relay, Closed = Fault
V
UL_FLT_COM
Uplink Fault Relay, Common
W
UL_FLT_NO
Uplink Fault Relay, Open = Fault
X
DL_FLT_NC
Downlink Fault Relay, Closed = Fault
Y
DL_FLT_COM
Downlink Fault Relay, Common
Z
DL_FLT_NO
Downlink Fault Relay, Open = Fault
a
SUM_FLT_NO
Summary Fault Relay, Open = Fault
b
SUM_FLT_NC
Summary Fault Relay, Closed = Fault
c
SUM_FLT_COM
Summary Fault Relay, Common
Notes:
1. These signals can be configured as EIA-485, 2-wire, half-duplex or EIA-422, 4-wire,
half-duplex.
2. In 2-wire mode, pins A and B are tied together as are pins C and D.
3. To select 2-wire operation, pin T is left open.
4. Tie pin T to ground for EIA-422 (4-wire) operation.
2–5