CRS-300 1:10 Redundancy Switch

MN/CRS300.IOM

Switch Connectors and Pinouts

Revision 19

3–19

o Pull the holder straight out, and then swing the holder away from the module.

Then, remove and replace the fuses as needed.

CAUTION – FOR CONTINUED OPERATOR SAFETY, ALWAYS REPLACE THE FUSES

WITH THE CORRECT TYPE AND RATING.

Finally, reseat the fuse holder in the IEC power module.

3.3.2.2 48V Direct Current (DC) Power Interface

Feature

Description

1

Power Cord Connector

2

Press Fit Fuse Holder (NOT USED)

DC Power Specifications

Input Power

50 watts, 2 Amps maximum

Input Voltage

48 volts DC (±20%) nominal (38-60 volts)

Connector Type

Corcom PS series

Mating Connector

Corcom GA210 or Molex 03-12-1026

Fuse Protection

While this interface features a fuse holder that is press-fit into the body of the IEC

power module, the CRS-300 chassis features an internal electronic resettable fuse.

Figure 3-8. Chassis DC Power Interface (CRS-250 DC Power Supply Module)

3.3.2.2.1 48V DC Operation –Power Application

Figure 3-9. Apply DC Power

To apply DC power to the CRS-300 (typical for each module):

First, plug the user-supplied, male keyed DC power lead connector into the mating female

connector until the lock tab engages. Number 18 AWG minimum wires are recommended.

Then, connect the user-supplied DC power leads to the power source.