1.2 CRS-300 Compatibility
Table 1-1 shows the Comtech EF Data modems that are compatible for use with the CRS-300
1:10 Redundancy Switch.
Table 1-1. CRS-300 Compatibility Table
Modem
Optional Switches
CDM-625/A
Note 1
CRS-280L IF Switch (L-Band)
CRS-350 ESC Switch (IDR Overhead)
CDM-570/A
Note 2
CRS-280 IF Switch (70/140 MHz)
CDM-570L/AL
Note 2
CRS-280L IF Switch (L-Band)
SLM-5650/5650A
CRS-280 IF Switch (70/140 MHz)
CRS-280L IF Switch (L-Band)
CRS-350 ESC Switch (IDR Overhead)
CDM-Qx
CRS-280 IF Switch (70/140 MHz)
Up to one modulator and one demodulator allowed per CDM-Qx.
CDM-QxL
CRS-280L IF Switch (L-Band)
Up to one modulator and one demodulator allowed per CDM-QxL.
CDM-710G/710GL
CDM-710
CDM-700
CRS-280 IF Switch (70/140 MHz)
CRS-280L IF Switch (L-Band)
CDM-600
Note 2
CRS-280 IF Switch (70/140 MHz)
CRS-350 ESC Switch (IDR Overhead)
CDM-600L
Note 2
CRS-280L IF Switch (L-Band)
CRS-350 ESC Switch (IDR Overhead)
Compatibility Notes:
1)
The CDM-625 and CDM-625A Advanced Satellite Modems, with available CDM-600
Emulator Mode, serve as operationally transparent replacement units for the CDM-600/L
Open Network Satellite Modems.
2)
The CDM-570A and CDM-570AL Satellite Modems can operate either in legacy CDM-570
Compatibility Mode or in the normal CDM-570A Mode. If the CDM-570A/AL is in a network
of CDM-570/Ls, then it will need to be configured for CDM 570 Compatibility mode.
3)
The CiM-25, Comtech EF Data’s low-cost Internet Protocol (IP) Monitor & Control (M&C)
interface for existing CEFD modems, is not compatible for use on modems operating within
a CRS-300 redundancy system. Taking this prohibition of use under further consideration,
the CiM-25 should not, under any circumstances, be connected to the Remote port on the
CRS-300’s CRS-230 Controller card for control of the Switch and modems.