beautypg.com

Troubleshooting, Manual ignition system, Continued) – Desa (V) CD36R(N User Manual

Page 33

background image

33

www.desatech.com

116035-01B

TROUBLESHOOTING

Manual Ignition System

(

Continued)

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

Fireplace produces unwanted odors

Fireplace shuts off in use

Burner backfiring during combustion

Gas odor even when control knob is in OFF

position

Gas odor during combustion

Dark residue on logs or inside of fireplace

1. Gas leak. See Warning statement

above

1. High or gusting winds

2. Low line pressure

3. Pilot is partially clogged

4. Inner vent pipe leaking exhaust gases

into system

5. Glass is too loose and air tight gasket leaks

in corners after usage

6. Bad thermopile or thermocouple

7. Vent cap improperly installed or blocked

1. Gas leak.

See Warning statement

above

1. Gas leak.

See Warning statement

above

1. Improper log placement

2. Air holes at burner inlet blocked

3. Burner flame holes blocked

4. Improper venting or excessive blockage

5. Excessive amounts of embers and pan

material

1. Locate and correct all leaks (see Check-

ing Gas Connections, page 23)

1. Fireplace has been tested for up to

40 mph winds. However, extreme con-

ditions may occur. See Lighting Instruc-

tions on page 26

2. Check local propane/LP or natural gas

company

3. Clean pilot (see Cleaning and Mainte-

nance, page 30

4. Locate and correct all vent connections

(see Installation Planning, page 9)

5. Tighten or replace glass door (see Re-

moving/Replacing Glass Door, page 24)

6. Replace faulty components

7. Check for proper installation or remove

debris or blockage.

1. Locate and correct all leaks (see Check-

ing Gas Connections, page 23)

1. Locate and correct all leaks (see Check-

ing Gas Connections, page 23)

1. Properly locate logs (see Installing Logs,

Lava Rock, and Glowing Embers, page 25)

2. Clean out air holes at burner inlets, Pe-

riodically repeat as needed

3. Remove blockage or replace burner

4. Have the vent system inspected, includ-

ing the termination cap. Remove any

restrictions or blackage

5. Clear excess embers from around the rear

main ports. Use a minimum of one layer

of smaller ember peices to acheive the

best glowing effect over the visible areas

WARNING: If you smell gas

• Shut off gas supply.

• Do not try to light any appliance.

• Do not touch any electrical switch; do not use any phone in your building.

• Immediately call your gas supplier from a neighbor’s phone. Follow the gas

supplier’s instructions

• If you cannot reach your gas supplier, call the fire department.

TROUBLESHOOTING

Manual Ignition System (Cont.)