beautypg.com

High altitude installation, Installing optional controls, Gas supply and piping – Desa (V) CD36R(N User Manual

Page 21: Continued

background image

21

www.desatech.com

116035-01B

CHECK GAS TYPE

Use proper gas type for the fireplace unit you are installing. If your

gas supply is not correct, do not install fireplace. See retailer where

you purchased the fireplace for proper fireplace according to your

gas type or to purchase gas conversion kit (see Accessories, page 43).

HIGH ALTITUDE INSTALLATION

When installing this fireplace in the USA at an elevation above

2000 feet (610 m), you may need to decrease the input rating

by changing the existing burner orifice to a smaller size. Reduce

input 4% for each 1000 feet (305 m) above sea level. Check with

your local gas company for proper derate procedure and orifice size.
When installing this fireplace in Canada at an elevation above

4500 feet (1372 m), Check with local or provincial code authorities.
Consult your local gas company to help determine the proper orifice

for your location.
For assistance with any high altitude installation contact DESA’s

Customer Service Department at 1-866-672-6040.

INSTALLING GAS PIPING TO FIREPLACE

CAUTION: For propane/LP units, never connect

fireplace directly to the propane/LP supply. This
heater requires an external regulator (not supplied).
Install the external regulator between the fireplace
and propane/LP supply.

WARNING: A qualified service person must con-

nect fireplace to gas supply. Follow all local codes.

Propane/LP

Supply Tank

External

Regulator

Vent

Pointing

Down

Figure 47 - External Regulator with Vent Pointing Down (Pro-

pane/LP Only)

Figure 45 - Connecting WRC Remote Control Electronic

Fireplace
Receptacle

Remote Control
Receiver

Ignition
Module Plug

Extension Cord

INSTALLATING OPTIONAL CONTROLS (Cont.)

Installing Optional Wireless Remote Control - Model WRC

Check Gas Type

HIGH ALTITUDE INSTALLATION

Installing Gas Piping to Fireplace

INSTALLING OPTIONAL WIRELESS REMOTE
CONTROL - MODEL WRC (Electronic Ignition)

Installing and Activating the Remote Receiver
1. Open bottom louver and locate the plug receptacle. The plug

receptacle is located either on the right or left side of cabinet.

2. The WRC model receiver does not require a battery. The re-

ceiver can be installed by first plugging the short extension

cord into the fireplace receptacle. Then plug the receiver unit

into the extension cord. Finally plug the ignition module plug

into the receiver unit (see Figure 45).

3. Activate the remote handset battery by removing the insulat-

ing tab on the back of the handset (see Figure 46). The battery

is included pre-installed.

4. Once the battery is activated the unit is ready to use.
5. Replace the bottom louver panel.

INSTALLING OPTIONAL CONTROLS

Continued

Battery Cover

12 Volt Battery

Back of
Handset

Pull to Remove
Insulation Tab

Figure 46 - Installing Battery into Back of Handset

GAS SUPPLY AND PIPING

Your DESA direct-vent fireplace has been tested and approved in

the USA for elevations from 0-2000 feet (610 m) and in Canada

at elevations from 0-4500 feet (1372 m).

GAS SUPPLY AND PIPING