M – metric system, N – imperial system, Pa – printing speed – Compuprint 6314 CDL User Manual
Page 16: Pa – backfeed speed
CDL – Programmer Manual
16
This command, since it is a label definition command, is a local command that is effective only on
the current label: the default value is the one set by the HEAD TEMPER. SELECTION parameter
mentioned above.
m – Metric system
After this command, the co-ordinates are read as tenths of a millimetre instead of hundredths of an
inch. To return to hundredths of an inch, you need to enter a subsequent command n.
n – Imperial system
After an m command, with a current n command the printer returns to the imperial system in which
all numerical parameters are read in hundredths of an inch (this is the default setting).
Pa – Printing speed
You can select the label printing speed with this command.
Since it is a label definition command, it is local.
a may be set at the following speeds:
a Speed
(ips
)
A 2
B 2
C 2
D 2,5
E 3
F 3,5
G
4
H 4,5
I 5
J 5,5
K
6
L 6,5
M 7
N 7,5
O
8
e.g. with command PG the printer prints the current label at a speed of 4 ips.
pa – Backfeed speed
With this command you can select the label backfeed speed (see command STX fnnn).
Since it is a label definition command, it is local.
a may be set at the following speeds:
24
Inches per second.
25
Default and max. speed.
26
Default speed for models with expander card.
27
Max. speed for models with expander card.