Bronkhorst RS232 interface User Manual
Page 41
Parameter
number
(DDE)
Parameter
name
Group
0
Group
1
Group
2
Process
number
FB
nr
(par)
Var
Type
Var
Length
Min
value
Max
value
Read
Write
Poll
Secured
Highly
Secured
Default Value
Description
2011-05-18 Page 4 of 5
FlowDDE database version
V3.64
DDE str
206
fSetpoint
2
18
33
3
f
-3.40282E+38
3.40282E+38
Yes
Yes
No
No
No
0
setpoint: wanted value for direct reading (in capunits, max.= capacity)
fSetpoint
207
Mass
20
33
23
f
-3.40282E+38
3.40282E+38
Yes
No
Yes
No
No
0
Mass in g
Mass
208
Manufacturer status register
4
119
1
c
8
Yes
No
No
No
No
Manufacturer Status register (64 diagnostic bits)
Mstatus
209
Manufacturer warning register
4
119
2
c
8
Yes
No
No
No
No
Manufacturer Warning register (64 diagnostic bits)
Mwarning
210
Manufacturer error register
4
119
3
c
8
Yes
No
No
No
No
Manufacturer Error register (64 diagnostic bits)
Merror
211
Diagnostic history string
4
119
4
c
-2
Yes
Yes
No
No
No
Diagnostic history string (contains history of diag codes)
DiagHist
212
Diagnostic mode
4
119
5
c
0
255
Yes
Yes
No
Yes
No
0
Diagnostic mode (0 = diagnostics off, 1 = diagnostics on)
DiagMode
213
Manufacturer status enable
4
119
6
c
0
255
No
Yes
No
No
No
0
Manufacturer Status enable (0-127 or 254 = disable all, 255 = enable all)
MStatEnabl
214
Analog output zero adjust
10
116
21
f
-3.40282E+38
3.40282E+38
Yes
Yes
No
Yes
No
0
Analog measure output, zero adjust
AnOutZA
215
Analog output span adjust
10
116
22
f
-3.40282E+38
3.40282E+38
Yes
Yes
No
Yes
No
1
Analog measure output, span adjust
AnOutSA
216
Analog input zero adjust
10
116
23
f
-3.40282E+38
3.40282E+38
Yes
Yes
No
Yes
No
0
Analog setpoint input, zero adjust
AnInZA
217
Analog input span adjust
10
116
24
f
-3.40282E+38
3.40282E+38
Yes
Yes
No
Yes
No
1
Analog setpoint input, span adjust
AnInSA
218
Sensor input zero adjust
10
116
25
f
-3.40282E+38
3.40282E+38
Yes
Yes
No
Yes
No
0
Sensor input, zero adjust
SensInZA
219
Sensor input span adjust
10
116
26
f
-3.40282E+38
3.40282E+38
Yes
Yes
No
Yes
No
1
Sensor input, span adjust
SensInSA
220
Temperature input zero adjust
10
116
27
f
-3.40282E+38
3.40282E+38
Yes
Yes
No
Yes
No
0
Sensor temperature input, zero adjust
TempInZA
221
Temperature input span adjust
10
116
28
f
-3.40282E+38
3.40282E+38
Yes
Yes
No
Yes
No
1
Sensor temperature input, span adjust
TempInSA
222
Adaptive smoothing factor
6
117
5
f
0
1
Yes
Yes
No
Yes
No
1.0
Sensor input filter adapt setting
ExpSmooAd
223
Slope setpoint step
18
33
24
i
0
32000
Yes
Yes
No
Yes
No
32000
Slope setpoint step. Setpoint step for the given slopetime
SlopeSetp
224
Filter length
6
117
6
i
0
255
Yes
Yes
No
Yes
No
1
Number of samples for average filter
FilterLen
225
Absolute accuracy
2
33
25
f
-3.40282E+38
3.40282E+38
Yes
No
No
No
No
0
Actual accuracy in current unit
fAccuracy
226
Lookup table index
3
33
26
c
0
255
Yes
Yes
No
No
No
0
Lookup table for linearisation index (x and y direction)
LookI
227
Lookup table X
3
33
27
f
-3.40282E+38
3.40282E+38
Yes
Yes
No
Yes
No
0
Lookup table for linearisation x
LookX
228
Lookup table Y
3
33
28
f
-3.40282E+38
3.40282E+38
Yes
Yes
No
Yes
No
0
Lookup table for linearisation y
LookY
229
Lookup table temperature index
3
33
29
c
0
255
Yes
Yes
No
No
No
0
Lookup table for linearisation at certain temperature index (z direction)
LookTempI
230
Lookup table temperature
3
33
30
f
-273.15
3.40282E+38
Yes
Yes
No
Yes
No
0
Lookup table for linearisation at certain temperature (z)
LookTemp
231
Valve maximum
8
114
25
f
0
24
Yes
Yes
No
Yes
No
0.2
Maximum current/voltage for valve
ValveMax
232
Valve mode
8
114
26
c
0
255
Yes
Yes
No
Yes
No
1
Valve output mode selection
ValveMode
233
Valve open correction
8
114
27
f
0
1.5
Yes
Yes
No
Yes
No
0.96
Valve open current/voltage correction (example: 0.96, Open = ValveOpen * 0.96)
VlvOpenCor
234
Valve zero hold
8
114
28
f
0
1
Yes
Yes
No
Yes
No
0
Valve hold current/voltage at %0 setp (example: 0.8, Hold = ValveOpen * 0.8)
VlvZeroHld
235
Valve slope
8
114
29
f
0
50
Yes
Yes
No
Yes
No
0.009
Valve slope time (seconds)
ValveSlope
236
IFI data
23
0
21
c
-2
Yes
Yes
No
No
No
0
IFI data dump protocol communication string
IFIData
237
Range used
20
19
115
20
c
-2
0
99
Yes
No
Yes
No
No
0
Piston Prover information about used sensors
RangeUsed
238
Fluidset properties
3
33
31
c
0
255
Yes
Yes
No
Yes
Yes
0
Fluidset properties
FldSetProp
239
Lookup table unit type index
3
33
12
c
0
255
Yes
Yes
No
Yes
Yes
0
Lookup table unit type
LUnitType
240
Lookup table unit type
3
33
13
c
20
Yes
Yes
No
Yes
Yes
Lookup table unit type name
LUnTypName
241
Lookup table unit index
3
33
16
c
0
255
Yes
Yes
No
Yes
Yes
0
Lookup table unit (unit LUTy)
LUnit
242
Lookup table unit
3
33
17
c
7
Yes
Yes
No
Yes
Yes
kg/s
Lookup table unit name
LUnitName
243
Capacity unit type index
3
29
c
0
255
Yes
Yes
No
Yes
No
0
Capacity (readout) unit type
CUnitType
244
Capacity unit type
3
30
c
20
Yes
Yes
No
Yes
No
Capacity (readout) unit type name
CUnTypName
245
Capacity unit type temperature
3
33
10
f
-273.15
3.40282E+38
Yes
Yes
No
Yes
No
0
Capacity (readout) unit type temperature (°C)
CUnTypTemp
246
Capacity unit pressure
3
33
11
f
0
3.40282E+38
Yes
Yes
No
Yes
No
1
Capacity (readout) unit type pressure (bar (a))
CUnTypPres
247
Capacity minimum
3
27
f
-3.40282E+38
3.40282E+38
Yes
Yes
No
Yes
No
0
Minimum capacity in output capacity units
CapMin
248
Capacity maximum
3
28
f
-3.40282E+38
3.40282E+38
Yes
Yes
No
Yes
No
1
Maximum capacity in output capacity units
CapMax
249
Formula type
3
113
17
i
0
65535
Yes
Yes
No
Yes
No
0
Formula type needed for conversion
FormulaTyp
250
Heat capacity
3
113
18
f
0
3.40282E+38
Yes
Yes
No
Yes
No
0
Heat capacity (Cp) (sensor conditions)
HeatCap
251
Thermal conductivity
3
113
20
f
0
3.40282E+38
Yes
Yes
No
Yes
No
0
Thermal conductivity (sensor conditions)
ThermCond
252
Viscosity
3
113
21
f
0
3.40282E+38
Yes
Yes
No
Yes
No
0
Dynamic viscosity (fluid conditions)
Viscosity
253
Standard flow
3
113
22
f
-3.40282E+38
3.40282E+38
Yes
Yes
No
Yes
No
1
Standard mass flow in ln/min (20°C, 1.01325 bar (a) ) air or g/h H2O equivalent
NormMasFlw
254
Controller speed
8
3
114
30
f
0
3.40282E+38
Yes
Yes
No
Yes
No
1
Controller speed factor (gain)
Kspeed
255
Sensor code
13
113
23
i
0
65535
Yes
Yes
No
Yes
Yes
0
Sensor code
SensorCode
256
Sensor configuration code
13
113
24
c
0
255
Yes
Yes
No
Yes
Yes
0
Sensor configuration code
SensorRevC
257
Restriction code
13
113
25
i
0
65535
Yes
Yes
No
Yes
Yes
0
Restriction code
RestrCode
258
Restriction configurator code
13
113
26
c
0
255
Yes
Yes
No
Yes
Yes
0
Restriction configuration code
RestrRevC
259
Restriction NxP
13
113
27
l
0
2147483648
Yes
Yes
No
Yes
Yes
0
Restriction NxP (proportional to air equivalent capacity of LFE)
RestrNxP
260
Seals information
13
113
28
c
16
0
255
Yes
Yes
No
Yes
Yes
V,V
Seals information (1st byte = other, 2nd = plunger seal)
Seals
261
Valve code
13
113
29
i
0
65535
Yes
Yes
No
Yes
Yes
0
Valve code
ValveCode
262
Valve configuration code
13
113
30
c
0
255
Yes
Yes
No
Yes
Yes
0
Valve configuration code
ValveRevC
263
Instrument properties
13
113
31
l
0
2147483648
Yes
Yes
No
Yes
Yes
0
Instrument properties
InstrProp
264
Lookup table frequency index
3
116
10
c
0
1
Yes
Yes
No
Yes
No
0
Lookup table for frequency index
LookFreqI
265
Lookup table frequency frequency
3
116
11
f
-3.40282E+38
3.40282E+38
Yes
Yes
No
Yes
No
0
Lookup table for frequency frequency
LFFreq
266
Lookup table frequency temperature
3
116
12
f
-273.15
3.40282E+38
Yes
Yes
No
Yes
No
0
Lookup table for frequency temperature
LFTemp
267
Lookup table frequency density
3
116
13
f
-3.40282E+38
3.40282E+38
Yes
Yes
No
Yes
No
0
Lookup table for frequency density
LFDensity
268
Lookup table frequency span adjust
3
116
14
f
-3.40282E+38
3.40282E+38
Yes
Yes
No
Yes
No
0
Lookup table for frequency span adjust
LFSpanAdj
269
Capacity unit index (ext)
3
19
65
15
c
0
255
Yes
Yes
No
Yes
No
0
Capacity (readout) unit index (extended unit table)
CUnit
270
Density actual
3
116
15
f
-3.40282E+38
3.40282E+38
Yes
No
Yes
No
No
0
Actual density, measured by instrument
DensityAct
271
Measured restriction
13
116
18
f
0
3.40282E+38
Yes
Yes
No
Yes
No
0
Measured restriction
RestrMeas
272
Temperature potmeter
3
116
8
c
0
255
Yes
Yes
No
Yes
No
0
Potmeter for sensor temperature compensation
TempPotm
273
Temperature potmeter gain
3
116
9
c
0
255
Yes
Yes
No
Yes
No
0
Gain for sensor temperature compensation
TempGain
274
Counter controller overrun correction
16
104
10
f
0
3.40282E+38
Yes
Yes
No
No
No
1
Counter controller overrun correction
CntrCConv
275
Counter controller gain
16
104
11
f
0
3.40282E+38
Yes
Yes
No
No
No
1
Counter controller gain
CntrCGain