beautypg.com

Bronkhorst RS232 interface User Manual

Page 25

background image

BRONKHORST

®

 

Page 25   

 

 

 

 

RS232 interface   

 

 

 

9.17.027 

46 

F0 

11110000 

80 

Parameter chained

Parameter index 16 

Capacity unit 

60 

Parameter type ’string

10 

Parameter index 16

47 

07 

 

Length of the answer 7 Bytes

48‐54 

 

 

6D 6C 6E 2F 6D 69 6E
Parameter value converted from hex to ASCII, the values do 
read : mln/min 

55 

71 

01110001 

00 

Parameter not chained

Parameter index 17 

Fluid name 

 

60 

Parameter type ’string’

11 

Parameter index 17

56 

0A 

 

Length of the answer 10 Bytes

57‐66 

 

 

4E 32 20 20 20 20 20 20 20 20
Parameter value converted from hex to ASCII, the values do 
read:  N2 

Total String 

:370302F1EC004D3632313233343541006D00555345525441470001AE1CD8CF3F800000F0076
D6C6E2F6D696E710A4E322020202020202020 \r\n 

 

 

ASCII character “SPACE” (20 HEX) is returned for every empty space in the string. 

 

3.10.5 Request measure 

 

Request measure from node 3 process 1, type integer

Nr 

Byte 

Layout 

Description 

Description per block 

 

 

Start 

06 

 

Length 6 

03 

 

Node 3 

04 

 

Command read

01 

00000001 

C  00  Process not chained (return)

Process 1 

P  01  Process 1 (return)

21 

00100001 

C  00  Parameter not chained (return)

Parameter type 1 

Process 1 

Parameter number 0 

Measure 

T  20  Parameter type ‘integer’ (return)

N  01  Parameter index 1 (return)

01 

‐0000001  P  01  Process 1

20 

‐0100000 

T  20  Parameter type ‘integer’
P  00  Parameter number (FBnr.) 0 (measure)

\r 

 

 

 

Carriage Return

End 

\n 

 

 

 

Line Feed

Total String 

:06030401210120\r\n

 

Answer from node 3 process 1

Nr  Byte 

Layout 

Description 

Description per block

 

 

Start 

06 

 

Length 6 

03 

 

Node 3 

02 

 

Command write 

01 

00000001 

00  Process not chained 

Process 1 

01  Process 1 (receiving process)

21 

00100001 

00  Parameter not chained

Parameter index 1