Bronkhorst RS232 interface User Manual
Page 39
Parameter
number
(DDE)
Parameter
name
Group
0
Group
1
Group
2
Process
number
FB
nr
(par)
Var
Type
Var
Length
Min
value
Max
value
Read
Write
Poll
Secured
Highly
Secured
Default Value
Description
2011-05-18 Page 2 of 5
FlowDDE database version
V3.64
DDE str
66
9
116
4
l
0
16777215
Yes
Yes
No
Yes
No
52A513
calibration register full scale input 2 ADC
CalRegFS2
67
ADC control register
9
114
4
l
0
4294967295
Yes
Yes
No
Yes
No
18904E
ADC control register
ADCcntrReg
68
Bridge potmeter
9
116
5
c
0
255
Yes
Yes
No
Yes
No
0
sensor bridge zero potmeter setting
BridgePotm
69
4
115
4
c
0
255
Yes
Yes
No
Yes
No
1
broadcast alarm messsage enable flag
AlarmEnble
70
Test mode
4
115
5
c
0
255
Yes
Yes
No
Yes
No
0
test mode selection (not active until cntrlmode has been set to value 5)
TestMode
71
9
115
6
c
1
32
Yes
Yes
No
Yes
No
1
channel selection ADC
ChanSelect
72
Normal step controller response
8
114
5
c
0
255
Yes
Yes
No
Yes
No
0
controller response for normal steps (128=normal, <128=slower, >128=faster)
ContrResp
73
Setpoint exponential smoothing filter
6
117
3
f
0
1
Yes
Yes
No
Yes
No
1.0
analog input filter constant (0=max, 1=min)
ErrInFilCo
74
Sensor exponential smoothing filter
6
117
4
f
0
1
Yes
Yes
No
Yes
No
1.0
sensor input filter constant (0=max, 1=min)
ExpSmooCon
75
Analog output zero scale
10
21
i
-32767
65535
Yes
Yes
No
Yes
No
32767
analog output correction factor zero scale (meas outp DSCM-A 0=0 other 32767=0)
AnOutCorZS
76
Analog output full scale
10
22
i
0
65535
Yes
Yes
No
Yes
No
2000
analog output correction factor full scale (meas outp 2000 = 1 * multiplication)
AnOutCorFS
77
Analog input zero scale
10
23
i
-32767
65535
Yes
Yes
No
Yes
No
32767
analog input correction factor zero scale (ext setp DSCM-A 0=0 other 32767=0)
AnInpCorZS
78
Analog input full scale
10
24
i
0
65535
Yes
Yes
No
Yes
No
2000
analog input correction factor full scale (ext setp 2000 = 1 * multiplication)
AnInpCorFS
79
Tuning mode
7
115
7
c
0
255
Yes
Yes
No
Yes
No
0
(auto)tuning mode selection (not active until cntrlmode has been set to value 6)
TuningMode
80
Valve default
8
114
6
c
0
255
Yes
Yes
No
Yes
No
0
valve type (needed for controlling behaviour)
DefVlvType
81
Global modify
12
0
19
c
0
255
Yes
Yes
No
No
No
0
contains number(s) of changed processes for indirect polling (0xXX / 0xFF)
GlobModify
82
Valve span correction factor
8
114
7
f
0
1
Yes
Yes
No
Yes
No
0.1
correction factor valve curve ratio high/low area
SpanCorr
83
Valve curve correction
8
114
8
c
-2
Yes
Yes
No
Yes
No
20,80
Valve curve correction for controller (max. factor*0.1, flow where factor = 1)
VlvCrvStps
84
8
114
9
c
-2
Yes
Yes
No
Yes
No
10,5000,10,5000
array with memberships for normal Fuzzy controller
MemShipNor
85
8
114
10
c
-2
Yes
Yes
No
Yes
No
1,10000,3750,20000
array with memberships for 0-open Fuzzy controller
MemShipOpn
86
IO status
12
20
114
11
c
0
255
Yes
Yes
No
Yes
No
4
IO status byte for jumper settings and LED signal modes
IOStatus
87
8
114
13
c
-2
Yes
Yes
No
Yes
No
-30000,-500,-50
array with neg nor output steps for Fuzzy contr.
FuzzStNeNo
88
8
114
14
c
-2
Yes
Yes
No
Yes
No
50,500,25000
array with pos nor output steps for Fuzzy contr.
FuzzStPoNo
89
8
114
15
c
-2
Yes
Yes
No
Yes
No
90,180,12000
array with open at 0 output steps for Fuzzy contr.
FuzzStOpen
90
Device type
13
113
1
c
6
Yes
No
No
No
No
DMFC
(FLOW-BUS) device type information string
DeviceType
91
BHTModel number
13
113
2
c
-2
Yes
Yes
No
Yes
No
F201C-FA
model number information string
ModelNum
92
Serial number
13
113
3
c
-2
Yes
Yes
No
Yes
Yes
SN999999A
serial number information string (to be changed by Bronkhorst only)
SerialNum
93
Customer model
11
113
4
c
-2
Yes
Yes
No
Yes
No
STANDARD
manufacturing configuration information string
MfrConfig
94
BHT1
14
118
1
c
-2
Yes
Yes
No
Yes
Yes
01,01,95
special BHT parameter (to be changed by Bronkhorst only)
BHT1
95
BHT2
14
118
2
i
0
65535
Yes
No
No
No
No
0
special BHT parameter
BHT2
96
BHT3
14
118
3
l
-3000000000
3000000000
Yes
No
No
No
No
0
special BHT parameter
BHT3
97
BHT4
14
118
4
i
0
65535
Yes
No
No
No
No
0
special BHT parameter
BHT4
98
BHT5
14
118
5
c
0
255
Yes
No
No
No
No
0
special BHT parameter
BHT5
99
BHT6
14
118
6
c
0
255
Yes
Yes
No
No
No
0
special BHT parameter
BHT6
100
BHT7
14
118
7
c
0
255
Yes
No
No
No
No
0
special BHT parameter
BHT7
101
BHT8
14
118
8
c
0
255
Yes
No
No
No
No
0
special BHT parameter
BHT8
102
BHT9
14
118
9
l
-3000000000
3000000000
Yes
No
No
No
No
0
special BHT parameter
BHT9
103
BHT10
14
118
10
c
0
1
No
Yes
No
Yes
Yes
0
special BHT parameter (to be changed by Bronkhorst only)
BHT10
104
Broadcast repeating time
8
114
16
c
0
255
Yes
Yes
No
Yes
No
128
broadcast repeating time (x5 ms) (old:height of open at 0 pulse train for valve)
PulseHight
105
Firmware version
13
20
113
5
c
6
Yes
No
No
No
No
VX.XX
revision number of firmware
Version
106
Pressure sensor type
20
115
9
c
0
255
Yes
Yes
No
Yes
No
0
type of pressure sensor
PressSensr
107
Barometer pressure
20
116
8
f
0
1200
Yes
Yes
No
No
No
1013.25
mbar atmospheric (central) barometer pressure
BaroPress
108
Sensor input zero scale
10
25
i
-32767
65535
Yes
Yes
No
Yes
No
32767
analog sensor signal input corr. factor zero scale (DSCM-A 0=0 other 32767=0)
AnIn1CorZS
109
Sensor input full scale
10
26
i
0
65535
Yes
Yes
No
Yes
No
2000
analog sensor signal input correction factor full scale (2000=1*multiplication)
AnIn1CorFS
110
Reference voltage input zero scale
10
27
i
-32767
65535
Yes
Yes
No
Yes
No
32767
analog Vref input correction factor zero scale (DSCM-A 0=0 other 32767=0)
AnIn2CorZS
111
Reference voltage input full scale
10
28
i
0
65535
Yes
Yes
No
Yes
No
2000
analog Vref input correction factor full scale (2000=1*multiplication)
AnIn2CorFS
112
Analog setpoint zero scale
10
29
i
-32767
65535
Yes
Yes
No
Yes
No
32767
analog setpoint output correction factor zero scale (DSCM-A 0=0 other 32767=0)
AnOu1CorZS
113
Analog setpoint full scale
10
30
i
0
65535
Yes
Yes
No
Yes
No
2000
analog setpoint output correction factor full scale (2000=1*multiplication)
AnOu1CorFS
114
Reset
12
115
8
c
0
255
No
Yes
No
No
No
0
reset facilities (program/alarm/batchcounter)
Reset
115
User tag
11
113
6
c
-2
Yes
Yes
No
No
No
USERTAG
user definable alias string
UserTag
116
Alarm limit maximum
15
97
1
i
0
41600
Yes
Yes
No
No
No
0
maximum limit for sensor signal to trigger alarm situation
AlrmMaxLim
117
Alarm limit minimum
15
97
2
i
0
41600
Yes
Yes
No
No
No
0
minimum limit for sensor signal to trigger alarm situation
AlrmMinLim
118
Alarm mode
15
97
3
c
0
255
Yes
Yes
No
No
No
0
alarm mode
AlrmMode
119
Alarm output mode
15
97
4
c
0
255
Yes
Yes
No
No
No
0
alarm relais activity mode during alarm situation
AlrmOutMod
120
Alarm setpoint mode
15
97
5
c
0
1
Yes
Yes
No
No
No
0
setpoint change enable during alarm situation
AlrmStpMod
121
Alarm new setpoint
15
97
6
i
0
32767
Yes
Yes
No
No
No
0
new/safe setpoint during alarm situation (until reset)
AlrmNwSetp
122
Counter value
16
104
1
f
0
3.40282E+38
Yes
Yes
Yes
No
No
0
actual counter value
CntrValue
123
Counter unit index
16
104
2
c
0
31
Yes
Yes
No
No
No
0
pointer to counter unit (classic counter unit table)
CntrUnit
124
Counter limit
16
104
3
f
0
3.40282E+38
Yes
Yes
No
No
No
0
counter limit/batch
CntrLimit
125
Counter output mode
16
104
4
c
0
255
Yes
Yes
No
No
No
0
counter relais activity mode when limit/batch has been reached
CntrOutMod
126
Counter setpoint mode
16
104
5
c
0
1
Yes
Yes
No
No
No
0
setpoint change enable during counter limit/batch situation (until reset)
CntrStpMod
127
Counter new setpoint
16
104
6
i
0
32767
Yes
Yes
No
No
No
0
new/safe setpoint at counter limit/batch situation (until reset) (normally = 0%)
CntrNwSetp
128
Counter unit
16
104
7
c
4
Yes
Yes
No
No
No
ln
counter readout unit (informative only for older devices)
CntrUntstr
129
Capacity unit
3
19
31
c
7
Yes
Yes
No
Yes
No
ln/min
capacity readout unit (informative only for older devices)
capunitstr
130
Counter mode
16
104
8
c
0
255
Yes
Yes
No
No
No
0
counter mode
CntrMode
131
Minimum hardware revision
13
113
7
c
1
Yes
No
No
No
No
VX.XX
minimum required hardware revision level for firmware version
HwRev
132
17
1
f
1E-10
10000000000
Yes
No
No
No
No
1.0
readout factor for direct reading (changes with readunit: local on module, R.O.)
RCreadfact
133
17
2
c
1
120
Yes
Yes
No
No
No
1
channel number for operation
channumber
134
17
3
c
0
120
Yes
Yes
No
No
No
0
master channel for master-slave operation
masterchan
135
17
4
i
0
32000
Yes
Yes
No
No
No
32000
RC slave factor
RCslavefct