AquaFit™Dual Temp (Spa-Side)

Symptom

Problem

Corrective Action

“OH” on LED Digital Display

Window

High Temperature Condition:

Do not enter spa water.

The water

temperature is above acceptable limits.
The water temperature has reached
110°F (≅43.3°C.). The system will shut
down.

1.

Remove the cover and
allow the water to cool.

2. Reset the power to the spa

by resetting the GFCI
breaker.


No further action is required

unless the water temperature

fails to return to acceptable
levels – in which case, call your

dealer for service.

3 Flashing Lights AND

“OH” on LED Digital Display
Window


High Limit Condition:

Do not enter spa water.

The water

temperature is above acceptable limits.
The water temperature has reached
118°F (≅47.8°C.). The system will shut
down.


Call your dealer for service.

3 Flashing Lights


System Error:


1.

Check the water level

2. Clean the filters.

3. If the problem persists, reset

the power to the spa by

resetting the GFCI breaker.

If the error is not resolved after
resetting the spa, call your dealer

for service.

Temperature Probe Failure:
If the LED Digital Display shows
32°F (≅0.0°C) or 136°F (≅57.8°C),

you have an open temperature
sensor. The heater is

deactivated.

Call the dealer for service.