Troubleshooting Guide

Heating System

Symptom

Problem

Corrective Action

1.

Temperature setting is too low

1.

Turn up the thermostat

2. Dirty

filter

2. Clean

filter

Does not heat

3. Flow switch out of adjustment

3. Call for service

1.

Temperature setting is to high

1.

Turn down the thermostat

Too hot

2. High limit tripped

2. Call for service

Flashing temperature of 34°F or
134°F appears on the display

Possible temperature sensor failure

Call for service

Electrical System

Symptom

Problem

Corrective Action

Will not turn on – in any mode

No power

Check circuit breaker and/or GFCI

Turns on by itself

Normal automatic daily power
filtration, or anti-freeze cycle

No action required

Light is out

Burned out bulb

Replace bulb

1.

Automatic 30-minute timer has
shut pump off

1.

Push JETS pad again to start
another 30-minute cycle

Pump shuts down unexpectedly
while in use

2. Motor over-heated and

automatic protective device

has shut down pump(s)

2. If pump(s) will not restart when

JETS pad is pushed, call for

service


Make sure that the equipment

panel vent area is not blocked.
Vent blockage can cause

serious damage to your

equipment.

1. Check

water

level

2. Clean

filter

If problem persists:

1.

Turn off power

2. Restart

the

system

If problem persists:

3 flashing LEDs appear on the
Top Side Control

Possible sensor errors

Call for service

Water System

Symptom

Problem

Corrective Action

Pulsating jets

Water level too low

Fill with water to 1” to 2” (2 to 5

centimeters) above the bottom of
the tile line

1. HydroTherapy

Jets

closed

1. Open

Jets

2. Diverter Valve turned

2. Turn the Diverter Valve

clockwise or counter
clockwise

3. Dirty

Filter

3. Clean

Filter

4. Air lock

4. Loosen pump union to allow air

to escape

No Jet Action, or action is poor

5. Gate valve closed

5. Open gate valve
1. Check

TA/pH

2. Test

and

adjust

The water is cloudy or has a smell

The water has a chemical

imbalance.

3. Change Water if necessary