Self-Diagnostic Control System

AquaFit™, AquaFit™Dual Temp (Pool-Side), AquaPro™

Symptom

Problem

Corrective Action

Non-functional

High Temperature Sensor:
Open high temperature sensor.

Heater is deactivated.

Call your dealer for service.

Non-functional temperature
sensor:

Open temperature sensor. Heater
is deactivated.

Call your dealer for service.

Water Flow Problem:
Pressure switch is not closed when

the pump is activated. Heater is

deactivated. Proper flow of water
is inhibited or pressure switch has

malfunctioned. Check for proper
water level, ensure pump is primed

and/or check for clogged filter.

Pressure switch may need to be
adjusted.

Call the dealer for service.

Pressure switch problem:

Pressure switch is closed, while
pump is deactivated. Pressure

switch may need to be adjusted.

Call your dealer for service.

Cool condition:

If the water temperature drops 20°F
(≅11°C) below the set temperature, the
low speed pump and the heater will
activate to bring the temperature within
15°F (≅8°C) of the set temperature.


No corrective action is required.

Freeze condition:

A potential freeze condition has been
detected (55°F / ≅12.8°C.)

No action is required.

The low speed pump will be activated along
with the heater. The spa will automatically
heat, until the spa is out of danger (65°F /
≅18.3°C.)