Belshaw Adamatic Snack Master Snack Food Frying System User Manual
Page 39
Belshaw Bros., Inc.
• www.belshaw.com • Phone 206-322-5474 • Fax 206-322-5425
Snack Master TS
MN-xxxxEN
17
6. Immerse the thermostat sensing bulb in a
pan of boiling water and set the thermostat
at about 212
°F/100°C. The continuity
tester’s indicator or light should go off. If
the indicator or light does not go off,
increase the temperature setting of the
thermostat until it does. Then recalibrate the
thermostat according to the manufacturer’s
instructions. If the indicator or light will not
go off at any setting or recalibration, then
the thermostat is defective.
Figure 5-3. Thermostat Terminals.
“B” terminals
“A” terminals