10 electrical specifications and timings, 1 absolute maximum ratings, 2 electrical characteristics – BECKHOFF ET1200 User Manual
Page 59: Electrical specifications and timings, Absolute maximum ratings, Electrical characteristics, Table 48: absolute maximum ratings, Table 49: operating conditions

Electrical Specifications and Timings
Slave Controller
– ET1200 Hardware Description
III-49
10 Electrical Specifications and Timings
10.1 Absolute Maximum Ratings
Table 48: Absolute Maximum Ratings
Symbol
Parameter
Condition
Min
Max
Units
V
CC
-V
SS
Supply voltage for
internal LDO
-0.3
5.5
V
I
CC
Supply current
Internal LDOs used for V
CC I/O
and
V
CC Core
110
mA
I
CC I/O
Supply current
V
CC I/O
sourced externally, LDO
used for V
CC Core
60
mA
I
CC Core
Supply current
V
CC I/O
and V
CC Core
sourced
externally
100
mA
V
ESC
ESD protection
Human body model, according to
MIL-STD-883E-3015.7 Class 1
2
kV
I
DC_ESD
Permanent current into
ESD protection diodes
Only in case of forward biased
ESD diodes. Input voltage above
V
CCI/O
or below V
SS
2
mA
NOTE: Supply current does not include output driver current for PDIs and LEDs.
10.2 Electrical Characteristics
Table 49: Operating Conditions
Symbol
Parameter
Min
Typ
Max
Units
V
CC
Power supply
3.0
5.0
5.5
V
V
CC I/O
I/O power supply
3.0
3.3
5.5
V
V
CC Core
Logic power supply
2.25
2.5
2.75
V
V
CC PLL
PLL power supply
2.25
2.5
2.75
V
V
CC I/O Ext
External I/O power supply
3.3
3.3
5.5
V
V
CC Core Ext
External logic power supply
2.5
2.5
2.75
V
V
CC PLL Ext
External PLL power supply
2.5
2.5
2.75
V
A
Ambient temperature
-40
85
°C