Commissioning
Name
Type
Description
Default value
• other values are not permissible;
TurnUPSOffWait
REG_DWORD
Maximum delay time in seconds for switching
off the UPS output voltage after initiating the
Windows shutdown. The permissible values
can differ from model to model (depending on
hardware).
180
BatteryReplaceNoti
fyEnable
REG_DWORD
Activates/deactivates the logging of the battery
change service interval warnings in the
Windows event log: UPS software v3.0.0.8
and higher.
0
BatteryReplaceNoti
fyWait
REG_DWORD
Delay time in months for the first battery
change warning. This element can adopt a
value of between 0 and 480 months. Other
values are not permissible. Implemented in the
UPS software v3.0.0.8 and higher.
60
Advanced Settings
KEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Services\UPS
Name
Type
Description
Default value
FirstMessageDelay
REG_DWORD
Delay time in seconds for the first power
fail message to the user
5
MessageInterval
REG_DWORD
Delay time in seconds for further power
fail messages to the user.
20