Avalon Firestyles Lopi Front Blower User Manual
Lopi front blower installation instructions
![background image](https://www.manualsdir.com/files/772848/content/doc001.png)
Lopi Front Blower
Installation Instructions
Page 1 of 2
17601771.docx — 11/15/12
© Travis Industries, Inc.
Compatibility
SKU 99000123 – Answer, Revere, 1750 Insert, 1250 Insert
SKU 99000126 – Freedom
Items Required
3/8” Nutdriver
Phillips Screwdriver
Slip Joint Pliers (if switching power cord to left side)
To Switch the Power Cord to the Left Side:
Use a pair of slip‐joint pliers to disconnect the strain relief which holds the power cord in place. With the
power cord slackened, the Molex connectors that attach the power cord to the blower assembly may be
disconnected. Pry the button plug from the left side of the blower assembly and insert it into the hole
on the right side. Pull the left side Molex connector out from behind the deflection plate and cut the
nylon tie that holds the wire back. Insert the Molex connector on the power cord through the hole on
the left side of the blower assembly and attach it to the left side Molex connector. Route the wire
directly behind the blower cage. Place the strain relief over the power cord (it should be in the same
location on the power cord as before – approximately 2” from where the wires split). Insert the strain
relief into the hole on the left side until the strain relief locks in place. Make sure the power cord, wires,
or Molex assembly do not protrude into the blower opening.