beautypg.com

Large pedestal (1750, olympic) – Avalon Firestyles 1750 Large Pedestal User Manual

Page 3

background image

Large Pedestal (1750, Olympic)

99200129

Page 3 of 4

12/21/07

© Travis Industries, Inc.

Outside Air Installation – Using the Outside Air Kit (99200139)

3" Dia. Flex Duct

(4' max. length)

Select a location between

framing members for the

wall penetration.

NOTE: If wall is thicker

than 8", attach the flex duct

to the hood then slide the

hood into place.

Hood with Rodent Screen

Silicone

Seal the area around

the tube to prevent

air from entering

through the wall.

Silicone

Remove the cover

plate on the pedestal.

Secure the flex duct to the

air duct assembly using

the included hose clamp.

Attach the outside air duct

assembly to the pedestal

with the same screws that

held the cover plate in

place.

b

c

a

Tuck insulation (included with the

pedestal) under both sides of the

pedestal and under the holes on the

base of the pedestal. This prevents air

from being

drawn from below

the pedestal.

e

Slide the hood

through the wall and

secure to the outside

wall with the two

included screws.

Cover Plate

d

Slide the cover plate over the flex duct

then attach the flex duct to the hood with

the included hose clamp. Secure the

cover plate to the wall with the included

screws (and drywall anchors if needed).

HINT: The flex must be fully stretched and

the ends cut square and flatted for it to fit

properly. The tube on the hood and air

duct may be crimped if necessary.

Min. 3"

Dia. Hole

8"