root@PrAMC-7211:~# fcu -uf /opt/motorola/rom/pramc-7211-cpu.fri

PTM control block init, PTMID get failed

This ipmc device supports legacy non-HPM.1 upgrade protocol.

UPGRADING BANK B ...

Booting from BANK B is highly suggested before upgrading the other bank.

********************[[[[[REPORT BEGIN]]]]]********************

OPERATION : Verify

RESULT : NOTICE

MESSAGE : forcing partrevision

OPERATION : Verify

RESULT : SUCCESS : compatible image found

MESSAGE : OEM:Emerson PROD:PrAMC-7211 PN: 0106824E02C REV: Rev C

VER:1.8 NAME:PHOENIX-BIOS

OPERATION : Write

RESULT : SUCCESS UPGRADING

MESSAGE : pramc-7211-cpu:Emerson:PrAMC-7211:0106824E02C:Rev

C:PHOENIX-BIOS:1.8

********************[[[[[ REPORT END ]]]]]********************

3. If you want to upgrade the current active bank, then mark the current standby bank to be

booted and reboot. Follow step

1

to upgrade this new inactive bank.

fcu -mb -d pramc-7211-cpu